PAGE 67
5.
Check the fuses in the control box. There are two fuses on the primary side and one on the
secondary side. Remove the fuses and check them with an Ohm meter.
6.
Check the limit switches. (For procedures, REFER TO SECTION 8.2 ON THE FOLLOWING
PAGE.)
7.
No power from the transformer: Check the voltage across the transformer’s secondary
terminals. It should read 110 to 120 volts.
8.
The solenoid on the control valve is not functioning. REFER TO SECTION 8.3.
9.
The foot pedal switch is not functioning properly. A voltage test may be run on the terminal strip
in the control box to determine if the foot switch is working properly.
WARNING: THERE IS LINE VOLTAGE PRESENT IN THE CONTROL BOX WHEN THE
MACHINE IS POWERED. THESE TESTS SHOULD BE PERFORMED BY A QUALIFIED
ELECTRICIAN.
TO TEST THE FOOT SWITCH:
Power the machine and place the selector switch in either the PUNCH or the SHEAR position.
Test the voltage between terminal #’s 5, 10 and ground.
With the pedal up, the voltage should read 110 to 120 volts between 5 and ground.
There should be no voltage reading between 10 and ground.
With the pedal depressed, the voltage should read 110 to 120 volts between 10 and ground.
There should be no voltage reading between 5 and ground.
IF THESE READINGS ARE NOT CORRECT, continue on with the following steps.
A.
Turn off the machine’s power and remove the cover on the foot pedal. Check for loose
connections.
B.
Make sure that the switches are adjusted properly. (You should hear two distinct "clicks"
approximately 1/2 inch (12mm) apart when depressing the pedal.) There is a set screw adjustment
on the pedal shaft to adjust the switches.
C.
Check the switches with an Ohm meter.
10.
Damage to the foot pedal cord: Check the continuity of the wires in the cord with an Ohm meter.
Make sure that the power to the machine is off and locked out. The wires must be disconnected
from the pedal and the terminal block.
11.
The pump to motor coupler is damaged. Loosen the set screws in the pump and motor flanges and
slide them apart. Inspect the coupler. If it is damaged, replace it.
Содержание FI-8510-20M
Страница 10: ...PAGE 9 FIGURE 1...
Страница 12: ...PAGE 11 FIGURE 2...
Страница 24: ...PAGE 21 FIGURE 6...
Страница 26: ...PAGE 23 FIGURE 7...
Страница 38: ...PAGE 35 FIGURE 15...
Страница 40: ...PAGE 37 FIGURE 16...
Страница 42: ...PAGE 39 FIGURE 17...
Страница 44: ...PAGE 41 11 Install the notcher table H and adjust the guard down to the proper height FIGURE 18...
Страница 48: ...PAGE 45 FIGURE 20...
Страница 50: ...PAGE 47 FIGURE 21...
Страница 52: ...PAGE 49 FIGURE 22...
Страница 56: ...PAGE 53 FIGURE 24...
Страница 58: ...PAGE 55 FIGURE 25...
Страница 62: ...PAGE 59 FIGURE 26...
Страница 64: ...PAGE 61 FIGURE 27...
Страница 68: ...PAGE 65 FIGURE 29...
Страница 74: ...PAGE 71 FIGURE 30...
Страница 76: ...PAGE 73 FIGURE 31...
Страница 80: ...PAGE 77 FIGURE 33...
Страница 82: ...PAGE 79 FIGURE 34...
Страница 84: ...PAGE 81 FIGURE 35...
Страница 88: ...PAGE 85 FIGURE 37...
Страница 90: ...PAGE 87 FIGURE 38...
Страница 92: ...PAGE 89 FIGURE 39...
Страница 94: ...PAGE 91 FIGURE 40...
Страница 96: ...PAGE 93 FIGURE 41...
Страница 100: ...PAGE 97 FIGURE 43 SERIAL S 4481 UP...