background image

 

GEN 2 WIRELESS LOCAL ALERT FEATURES 

 

Three alarm types: Flashing red LED, alarm tones, and custom message display  

 

Sounds a unique alarm tone sequence when it receives multiple notifications 

 

Each alarm setting is configurable in Scigiene Premier. 

 

The LCD shows device name, custom message or sensor reading, and notification time 

 

Stores up to 10 notifications/readings 

 

Reports the number of notifications and sensor readings saved on the Local Alert to Scigiene Premier 

 

Battery-powered, line-powered, or both 

 

Configurable alarm and snooze intervals 

 

Configurable Heartbeat and Poll Rate (how often the Local Alert checks the gateway for notifications) 

 

Displays the status bar while on line power 

 

Instantly receives notifications from the gateway when using line power and in a sleep state 

 

Power-saving features automatically enabled to extend battery life 

 

Wireless range of 1,200+ feet through 12+ walls

1

 

 

Frequency-Hopping Spread Spectrum (FHSS) 

 

Best-in-class interference immunity 

 

Best-in-class power management for longer battery Iife

2

 

 

Encrypt-RF Security (Diffie-Hellman Key Ex AES-128 CBC for sensor data messages) 

 

Data logs 2000 to 4000 readings if the gateway connection is lost (non-volatile flash, persists through the power 
cycle): 

o

  10-minute heartbeats = - 22 days 

o

  2-hour heartbeats = - 266 days 

 

Over-the-air updates (future-proof) 

 

Free Scigiene Premier Basic Online Wireless Sensor Monitoring and Notification System to configure sensors, 
view data, and set alerts to be sent via SMS text, email, or call. 

1 Actual range may vary depending on the environment. 
2 Battery life is determined by the sensor reporting frequency and other variables. Other power options are also available. 
 

LOCAL ALERT - PRINCIPLE OF OPERATION 

The GEN 2 Wireless Local Alert device receives messages (notifications and sensor readings) from Scigiene Premier and 
delivers alarms via a flashing red LED, tones, and LCD. The Local Alert receives messages, generated in Scigiene 
Premier, wirelessly through a gateway connected to the Scigiene Premier server, so notifications can be received locally 
where someone is most capable of responding to a critical condition. 

The Local Alert displays notifications and sensor messages. Notifications are messages generated by Scigiene Premier’s 
notification system when a sensor sends data through a GEN 2 Gateway after it detects a change to a user-defined 
condition. Notifications can be triggered by sensor specific conditions or even conditions in the Scigiene Premier system. 
Sensor messages are sensor data messages forwarded from Scigiene Premier to the Local Alert through the Local Alert's 
gateway. These sensor messages can be generated when data from any GEN 2 Sensor is received in Scigiene Premier. 

When the Local Alert receives a notification, it can set off an audio-visual alarm comprised of a loud 85 dB buzzer, an 
ultra-bright red flashing LED, and an LCD displaying a custom message to alert the user of a critical condition in their 
sensor network. After the alarm sounds, with a press of the button, the user can clear the alarm, view a custom 
notification, the time the notification was sent, and which device detected the critical condition. The button can also be 
used to clear notifications and reset the device. 

When notifications are cleared on the Local Alert an acknowledgment message is also sent from the Local Alert to 
Scigiene Premier through the Local Alert's gateway. Be aware that acknowledging/clearing notifications in Scigiene 
Premier will not clear notifications already received on the Local Alert. Messages already received can only be removed 
from the Local Alert by button holds, resetting the Local Alert, power cycling, or being overridden by more recent 
messages. 

The Local Alert can be set as a device to receive notifications using Scigiene P

remier’s standard notification interface. 

Within this interface the Local Alert’s specific alarms (LED, buzzer, scrolling message, backlight) can be set along with all 
of the other standard notification features already available. The Local Alert can also be set up to display sensor 
messages from other sensors on your Scigiene Premier account. The Local Alert does not communicate directly with 
sensors. The Local Alert receives all messages (notifications and sensor messages) from Scigiene Premier. 

 

Содержание RFR-0541-2

Страница 1: ...1 GEN 2 Wireless Local Alert RFR 0541 2 User Guide IMPORTANT Powering off the Local Alert will delete any saved notifications or sensor readings however any configuration changes will be saved...

Страница 2: ...G NETWORK 6 III SET UP IN SCIGIENE PREMIER 7 ADD DEVICE 7 SET UP 7 VALIDATION 8 ACTIONS 8 NOTIFICATIONS 9 SENSOR READINGS 10 IV LOCAL ALERT OVERVIEW IN SCIGIENE PREMIER 11 MENU SYSTEM 11 DETAILS VIEW...

Страница 3: ...GEN 2 WIRELESS LOCAL ALERT QUICK START 1 Create an Scigiene Premier user account 2 Add wireless gateway s and sensor s to the network 3 Add the Local Alert device to the sensor network 4 Power on the...

Страница 4: ...sages The left number indicates the current message being displayed The right number indicates how many total messages are on the Local Alert 9 Signal Strength This icon indicates the signal strength...

Страница 5: ...be received locally where someone is most capable of responding to a critical condition The Local Alert displays notifications and sensor messages Notifications are messages generated by Scigiene Pre...

Страница 6: ...dix A for more detailed information on the Local Alert s behaviors II ORDER OF OPERATIONS It s important to understand and follow the order of operations for activating the GEN 2 Local Alert If perfor...

Страница 7: ...to add a sensor These can both be located on the label on the side of your device 3 Adding your device You will need to enter the Device ID and the Security Code from your sensor in the corresponding...

Страница 8: ...and to speed up this process 3 Make sure Local Alert is powered Attach the included antenna and switch on the Local Alert see the Powering Sensor On and Attach Antenna sections for help in this area O...

Страница 9: ...the notification Click the icons next to the selected Local Alert to activate deactivate different alarms Click the right arrow button to advance to the sensor selection screen The message sent to the...

Страница 10: ...lert Insert batteries and or line power and slide the switch on left side to the On position Antenna Orientation In order to get the best performance out of your GEN 2 device it is important to note p...

Страница 11: ...corner of the sensor icon denotes its status Green indicates the Local Alert is checking in and within user defined safe parameters Red indicates the Local Alert has met or exceeded a user defined th...

Страница 12: ...ng information about the state of the Local Alert when the message was transmitted See Sensor State explained below Alert Sent Boolean indicating if this reading triggered a notification to be sent fr...

Страница 13: ...On state before scrolling to the next message K Time Zone Offset Sets the time on the Local Alert to the same time zone as the Scigiene Premier account L LCD Contrast Increasing LCD contrast will dark...

Страница 14: ...grade security at every DATA SECURITY ON THE GATEWAY GEN 2 Gateways are designed to prevent prying eyes from accessing the data that is stored on the sensors and Local Alert devices Gateways do not r...

Страница 15: ...cation was generated in Scigiene Premier 1 Check the Heartbeat on the gateway that the Local Alert is connected to in Scigiene Premier The notification must get to the gateway before being sent to the...

Страница 16: ...orking contact Scigiene Support 3 The Local Alert can be powered from battery and or line power When on battery only a battery icon will appear in the status bar at the top of the display If this icon...

Страница 17: ...hirty seconds of viewing a notification reading without any user interaction thebacklight willturn offautomatically Pressing the button at this point will turn it back on Button Pressing the button wh...

Страница 18: ...18 VIII LOCAL ALERT BEHAVIORAL FLOW DIAGRAM...

Страница 19: ...ithout backlight LED One Ultra Bright Red LED 1630 mcd 110 x 45 Viewing Angle Buzzer 85 dB 30 cm 2 5 KHz 500 Hz Enclosure ABS plastic Dimensions 4 0 x 4 0 x 1 6 in 101 6 x 101 6 x 40 64 mm Excluding a...

Страница 20: ...validRMA number provided byScigiene Customer acknowledges that replacement products may be repaired refurbished or tested and found to be complying Customer shall bear the risk of loss for such retur...

Страница 21: ...radio transmitter IC 9794A RFSC1 has been approved by Industry Canada to operate with the antenna types listed on previous page with the maximum permissible gain and required antenna impedance for ea...