THE LOCAL ALERT INTERFACE 

 

 

 

1. Message Type 

This line will either indicate a notification or sensor message. 

2. Device 

The name of the sensor in Scigiene Premier. 

3. Message 

For notifications, these three lines will contain a custom or auto-generated message 
identifying the notification. For sensor messages, these three lines will contain the sensor 
data. These messages can be up to 63 characters long, beyond that the message will be 
clipped. 

4. Time 

The time the notification or sensor message was generated. This will align with the 
account time zone. 

5. Sound 

When this icon is present, the buzzer alarm is enabled. 

6. Lights 

When this icon is present, the LED alarm is enabled. 

7. Screen 

When this icon is present, text LCD alarms are enabled. 

8. Messages 

The left number indicates the current message being displayed. The right number 
indicates how many total messages are on the Local Alert. 

9. Signal Strength 

This icon indicates the signal strength between the ALTA Gateway and the Local Alert 
with up to four bars. Each bar indicates 25%. If there is a small x appearing above the 
signal bars, there is less than 0% signal strength. If the signal bars are replaced with a 
large X, the Local Alert is not connected to a gateway and will be unable to receive new 
messages from Scigiene Premier. 

10. Battery 

This icon indicates the battery level of the Local Alert. There are six bars or three pairs of 
bars. Each bar represents 16%. At 0% there will be 0 bars. 

11. Time 

Current time in military format with hours and minutes. The time zone is a configuration 
matched to the time zone of the Local Alert's account. This configuration is sent when any 
configuration is set in Scigiene Premier, then saved. 

 

 

 

Содержание RFR-0541-2

Страница 1: ...1 GEN 2 Wireless Local Alert RFR 0541 2 User Guide IMPORTANT Powering off the Local Alert will delete any saved notifications or sensor readings however any configuration changes will be saved...

Страница 2: ...G NETWORK 6 III SET UP IN SCIGIENE PREMIER 7 ADD DEVICE 7 SET UP 7 VALIDATION 8 ACTIONS 8 NOTIFICATIONS 9 SENSOR READINGS 10 IV LOCAL ALERT OVERVIEW IN SCIGIENE PREMIER 11 MENU SYSTEM 11 DETAILS VIEW...

Страница 3: ...GEN 2 WIRELESS LOCAL ALERT QUICK START 1 Create an Scigiene Premier user account 2 Add wireless gateway s and sensor s to the network 3 Add the Local Alert device to the sensor network 4 Power on the...

Страница 4: ...sages The left number indicates the current message being displayed The right number indicates how many total messages are on the Local Alert 9 Signal Strength This icon indicates the signal strength...

Страница 5: ...be received locally where someone is most capable of responding to a critical condition The Local Alert displays notifications and sensor messages Notifications are messages generated by Scigiene Pre...

Страница 6: ...dix A for more detailed information on the Local Alert s behaviors II ORDER OF OPERATIONS It s important to understand and follow the order of operations for activating the GEN 2 Local Alert If perfor...

Страница 7: ...to add a sensor These can both be located on the label on the side of your device 3 Adding your device You will need to enter the Device ID and the Security Code from your sensor in the corresponding...

Страница 8: ...and to speed up this process 3 Make sure Local Alert is powered Attach the included antenna and switch on the Local Alert see the Powering Sensor On and Attach Antenna sections for help in this area O...

Страница 9: ...the notification Click the icons next to the selected Local Alert to activate deactivate different alarms Click the right arrow button to advance to the sensor selection screen The message sent to the...

Страница 10: ...lert Insert batteries and or line power and slide the switch on left side to the On position Antenna Orientation In order to get the best performance out of your GEN 2 device it is important to note p...

Страница 11: ...corner of the sensor icon denotes its status Green indicates the Local Alert is checking in and within user defined safe parameters Red indicates the Local Alert has met or exceeded a user defined th...

Страница 12: ...ng information about the state of the Local Alert when the message was transmitted See Sensor State explained below Alert Sent Boolean indicating if this reading triggered a notification to be sent fr...

Страница 13: ...On state before scrolling to the next message K Time Zone Offset Sets the time on the Local Alert to the same time zone as the Scigiene Premier account L LCD Contrast Increasing LCD contrast will dark...

Страница 14: ...grade security at every DATA SECURITY ON THE GATEWAY GEN 2 Gateways are designed to prevent prying eyes from accessing the data that is stored on the sensors and Local Alert devices Gateways do not r...

Страница 15: ...cation was generated in Scigiene Premier 1 Check the Heartbeat on the gateway that the Local Alert is connected to in Scigiene Premier The notification must get to the gateway before being sent to the...

Страница 16: ...orking contact Scigiene Support 3 The Local Alert can be powered from battery and or line power When on battery only a battery icon will appear in the status bar at the top of the display If this icon...

Страница 17: ...hirty seconds of viewing a notification reading without any user interaction thebacklight willturn offautomatically Pressing the button at this point will turn it back on Button Pressing the button wh...

Страница 18: ...18 VIII LOCAL ALERT BEHAVIORAL FLOW DIAGRAM...

Страница 19: ...ithout backlight LED One Ultra Bright Red LED 1630 mcd 110 x 45 Viewing Angle Buzzer 85 dB 30 cm 2 5 KHz 500 Hz Enclosure ABS plastic Dimensions 4 0 x 4 0 x 1 6 in 101 6 x 101 6 x 40 64 mm Excluding a...

Страница 20: ...validRMA number provided byScigiene Customer acknowledges that replacement products may be repaired refurbished or tested and found to be complying Customer shall bear the risk of loss for such retur...

Страница 21: ...radio transmitter IC 9794A RFSC1 has been approved by Industry Canada to operate with the antenna types listed on previous page with the maximum permissible gain and required antenna impedance for ea...

Отзывы: