9.3.3.1.5 ACCUMULATOR RESETTING MODES
NXperience
NXperience Mobile
Android
iOS
Figure 10 –
Accumulator Resetting Modes
•
By Software:
If selected, it allows you to reset the accumulator by software.
•
Periodic:
If selected, it allows you to reset the accumulator daily, weekly, monthly, and you can add time, day of the week or a date.
9.3.3.2
"EVENT LOG" OR "LOGS CONTROL" MODES
NXperience
NXperience Mobile
Android
iOS
Figure 11 –
"Event Log" or "Logs Control" Modes
•
Tag:
Allows you to configure a 16-character name for the digital channel. This name will be used to identify the channel in a data download.
•
Input Mode:
Allows you to select the digital input mode. In this example, the selected mode must be "Event Log" or "Logs Control". If you select
the "Logs Control" mode, the start and/or stop of logs mode by digital input must be selected for the configuration to take effect.
•
Sensor Type:
Allows you to configure the sensor type to be connected to the digital input: PNP, NPN or Dry Contact.
•
Event Edge:
Allows you to configure the desired event edge. This way, the device will log events each time the configured edge is detected at
the digital input. In "Event Log" mode you can configure to log on the Rising, Falling or Both edges. In the "Logs Control" mode, it is possible to
select to control logs in the Rising, Falling, Both edges - Logs at logical level "1" or Both - Logs at logical level "0".