![SCIFIT ISO7000R Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/scifit/iso7000r/iso7000r_service-manual_1217561041.webp)
41
J.
Wireless Heart Rate PCB Replacement
(Use this procedure for
ISO7000R’s with serial numbers 570-005296 thru 570-005408.)
1. Remove the five (5) console screws in the console back (P2304), using a
Philips screwdriver.
2. Disconnect all cables running to the upper PCB (P2160) and remove
console face (P2303) from the unit. Make sure the cables do not fall
into the neck of the unit.
3. Locate the wireless heart rate mounting location.
4. Peel the old wireless heart rate PCB (P2501) from the console face.
5. Clean the wireless heart rate mounting location.
6. Apply adhesive to the back of the wireless heart rate PCB.
7. Mount the wireless heart rate PCB.
8. Reconnect all cables to the upper PCB (as shown below).
•
Plug the wireless heart rate PCB back into the upper PCB. It plugs
into the bottom 3-pin header on the right side of the upper PCB (as
shown in the drawing).
•
The contact heart rate PCB has a cable coming up from the neck of
the unit. This plugs into the top, 3-pin header on the right side of the
upper PCB, above the wireless heart rate header (as shown in the
drawing).
Содержание ISO7000R
Страница 66: ...66...
Страница 67: ...67 See page 68 for breakdown of item numbers 59 and 60...
Страница 69: ...69 See page 70 for breakdown of item number 64...
Страница 71: ...71...
Страница 74: ...74 B Assembly Drawings and Part List 570 005000 thru 570 005295...
Страница 75: ...75...
Страница 76: ...76 See page 77 for breakdown of item numbers 59 and 60...
Страница 78: ...78 See page 79 for breakdown of item number 64...
Страница 80: ...80...