29
3. Remove the six (6) screws holding the upper PCB to the console face.
This will free the upper PCB and overlay from the plastic console. Do not
touch any components on the upper PCB. Touching components
could cause static damage.
4. Install the new upper PCB.
5. Reinsert the six (6) screws through the upper PCB and into the console
face. Tighten.
6. Reconnect all cables to the upper PCB.
•
Plug the wireless heart rate PCB back into the upper PCB. It plugs
into the bottom 3-pin header on the right side of the upper PCB (as
shown in the drawing).
•
The contact heart rate PCB has a cable coming up from the neck of
the unit. This plugs into the top, 3-pin header on the right side of the
upper PCB, above the wireless heart rate header (as shown in the
drawing).
•
The ribbon cable plugs into the bottom ribbon cable header on the right
side of the upper PCB (as shown in the drawing).
•
The FITKEY ribbon cable (P2418) plugs into the FITKEY ribbon cable
header on the upper PCB. This header is located just above the
contact heart rate header (as shown in the drawing).
•
There are two (2) gray Telco cables. The cable from the 8VDC jack
affixed to the console back connects to the 8-pin, +8VDC power
header on the upper PCB. The other cable from the COMM jack
affixed to the console back connects to the 8-pin, C-Safe header.
7. Verify connections.
8. Match the console and face up to each other and install the five (5)
console screws, using a Philips screwdriver.
9. The model of machine must be defined. (Rotate the pedals to power up
the upper display to perform this next procedure.) When the display lights
up, see if “UNDEFINED” appears in the top window. If so, use the UP
arrow until the correct setting is displayed for your unit. The correct
setting for your unit is “BI RCMBT” or “ISO7000R”. If no unit type
appears in the top window upon power up, the display has probably been
preset at the factory. To verify this, hold the SCAN, SELECT, and PAUSE
for three seconds until “FACTORY SETTINGS” appears, then release.
Do not continue to hold keys once this appears. Press ENTER once.
If “BI RCMBT” or “ISO7000R” appears in the top window, press ENTER
eight (8) times until “UPDATING” appears. If “BI RCMBT” or
“ISO7000R” doesn’t appear in the top window, press and hold SELECT
and the UP or DOWN arrow simultaneously until “BI RCMBT” or
“ISO7000R” does appear.
10. Verify operations of the unit by using different programs.
Содержание ISO7000R
Страница 66: ...66...
Страница 67: ...67 See page 68 for breakdown of item numbers 59 and 60...
Страница 69: ...69 See page 70 for breakdown of item number 64...
Страница 71: ...71...
Страница 74: ...74 B Assembly Drawings and Part List 570 005000 thru 570 005295...
Страница 75: ...75...
Страница 76: ...76 See page 77 for breakdown of item numbers 59 and 60...
Страница 78: ...78 See page 79 for breakdown of item number 64...
Страница 80: ...80...