6. Plug the heart rate PCB back into the upper PCB. It plugs into the
centermost, 3-pin Molex header.
7. Reinsert the upper PCB assembly into the front of the console.
8. Reinstall the two (2) outer countersunk screws in the back of the plastic
console.
9. Reconnect all cables to the upper PCB.
•
The contact heart rate PCB has a cable coming up from the neck
of the unit. This plugs into the outermost, 3-pin Molex header next
to the wireless heart rate PCB header.
•
When looking at the back of the upper PCB, the Telco cables plug
in along the left edge. The 6-pin plugs into the top plug and the 8-
pin plugs into the bottom plug.
•
If your unit has Cardio Key, the cable plugs into the serial port,
which is the 4-pin Molex header lower right corner.
•
If your unit has Broadcast Vision, Cardio Theater, etc., the cable
connects to the 8-pin header located at the bottom center of the
upper PCB.
10. Place the display assembly back onto the mounting plate and install the
four (4) display mounting screws.
11. The model of machine must be defined. (Rotate the pedals to power up
the upper display to perform this next procedure.) When the display lights
up, see if “ELLIPTICAL” appears in the top window. If so, use the UP
arrow until the correct setting is displayed for your unit. The correct
setting for the ISO7000R is “BI RCMBT”. Press ENTER to save. If no
unit type appears in the top window upon power up, the display has
probably been preset at the factory. To verify this, hold the SCAN and
ENTER buttons at the same time until a language type appears, then
release. With either “ENGLISH” or “GERMAN” displayed, press ENTER
to display the unit type. If the unit type is correct, press ENTER seven
times to exit the mode. If the correct unit type is not displayed, press
ENTER seven times to exit the mode, then follow step 12 to correct.
12. Press SCAN, SELECT, and PAUSE for five to six seconds to clear the E-
Prom on the upper PCB. “ELLIPTICAL” will appear in the top window.
Use the UP or DOWN arrow keys until the correct unit setting is
displayed. Once the correct setting appears in the top window, press
ENTER to save and exit.
Cardio Key/ Broadcast or Cardio Theatre Set Up: If you have Cardio
Key, Broadcast Theatre, or Cardio Theatre, press SCAN and ENTER at
the same time until a language type appears. Press ENTER five times
until “CARDIO KEY” or “CSAFE COMM” appear in the top window. Use
the UP or DOWN arrow to toggle between settings. The setting for Cardio
Key is “CARDIO KEY”. The correct setting for Broadcast or Cardio
Theatre is “CSAFE COMM”. Press ENTER three times to exit the mode.
Содержание ISO7000R
Страница 66: ...66...
Страница 67: ...67 See page 68 for breakdown of item numbers 59 and 60...
Страница 69: ...69 See page 70 for breakdown of item number 64...
Страница 71: ...71...
Страница 74: ...74 B Assembly Drawings and Part List 570 005000 thru 570 005295...
Страница 75: ...75...
Страница 76: ...76 See page 77 for breakdown of item numbers 59 and 60...
Страница 78: ...78 See page 79 for breakdown of item number 64...
Страница 80: ...80...