SUM Command (Long Summary Event Report)
The
SUM
command displays a long summary event report (see
TRI Command
below). The
long summary event report is displayed on all ports with AUTO = Y whenever an event is
generated.
To view a summary event report, enter the command
=>
SUM |ACK|
n
| N(ext) | <ENTER>
where:
no parameters Display the newest chronological summary event.
ACK
Acknowledge the oldest unacknowledged summary event report
available on this port, or if a number is supplied, acknowledge the
specified summary.
n
Display (or acknowledge if ACK present) the summary event with this
corresponding number in the
HIS E
command.
N(ext)
View oldest unacknowledged summary event report.
TAR Command (Display Relay Element Status)
The
TAR
command displays the status of front-panel target LEDs or relay elements, whether
they are asserted or deasserted. The elements are represented as Relay Word bits and are listed
in rows of eight, called Relay Word rows. The first 2 rows correspond to Table 10.8. All rows
of the Relay Word are described in
Section 9: Setting the Relay
.
A Relay Word bit is either at a logical 1 (asserted) or a logical 0 (deasserted). Relay Word bits
are used in SEL
OGIC
control equations. See
Section 9: Setting the Relay
and
Appendix G:
Setting SEL
OGIC
Control Equations
.
The
TAR
command does not remap the front-panel target LEDs, as is done in some previous
SEL relays. But execution of the equivalent
TAR
command via the front-panel display does
remap the bottom row of the front-panel target LEDs (see Figure 11.3, pushbutton OTHER).
The
TAR
command options are:
TAR
n k
Shows Relay Word row number
n
(0–67).
k
is an optional
parameter to specify the number of times (1–32767) to
repeat the Relay Word row display. If
k
is not specified,
the Relay Word row is displayed once.
TAR
name k
Shows Relay Word row containing Relay Word bit
name
(e.g.,
TAR 50P1
displays Relay Word Row 3). Valid
names are shown in Table 9.3 and Table 9.4.
k
is an
optional parameter to specify the number of times (1–
32767) to repeat the Relay Word row display. If
k
is not
specified, the Relay Word row is displayed once.
TAR R
Clears front-panel tripping target LEDs; TRIP, TIME,
COMM, SOTF, 50_51, A, B, C, G, Zone 1, Zone 2, and
Zone 3. Unlatches the trip logic for testing purposes (see
Figure 5.1 and Figure 5.4). Shows Relay Word Row 0.
Содержание SEL-311L
Страница 6: ......
Страница 8: ......
Страница 26: ......
Страница 54: ......
Страница 144: ......
Страница 203: ...Date Code 20010625 Trip and Target Logic 5 27 SEL 311L Instruction Manual Figure 5 12 DCUB Logic ...
Страница 216: ......
Страница 252: ......
Страница 302: ......
Страница 338: ......
Страница 480: ......
Страница 484: ......
Страница 486: ......
Страница 502: ......
Страница 532: ...12 28 Standard Event Reports and SER Date Code 20010625 SEL 311L Instruction Manual 4 ...
Страница 552: ......
Страница 554: ......
Страница 574: ......
Страница 576: ......
Страница 596: ......
Страница 602: ......
Страница 628: ......
Страница 656: ......
Страница 662: ......
Страница 664: ......
Страница 688: ......
Страница 700: ......
Страница 716: ......
Страница 722: ......
Страница 734: ......