7 Troubleshooting
EN
DSM 650‐RC / DSM 800‐RC
31
7 Troubleshooting
Only suitably knowledgeable, qualified professional technicians may perform repairs on the machine!
Malfunction
Cause
Rectification
Machine runs out‐of‐centre
during grinding.
Grinding pattern is uneven.
Tools are damaged or worn.
Replace tools.
Change type of the tool.
Tool has come loose.
Make sure that the number and arrangement
of the tools are the same.
Belt is torn.
Tool mounts [51, Fig. O] can be rotated in
dependently of each other: Lower belt needs
to be replaced.
Lower gears [52, Fig. O] can be turned by
hand:
Upper belt needs to be replaced.
Battery charge indicator
[22, Fig. C] flashes red.
Drive battery is too weak.
Recharge drive battery for at least one hour
(
!
Chapter 3.5 ‐ page 26).
Grinding drive switches off
during the grinding.
Machine is overloaded.
Swivel weight elements to the rear [C,
Fig. N]; press the
RESET button [17, Fig. B]
and start up the grinding drive.
Reduce tool speed.
Change type of the tool.
Faulty power supply.
Check the connecting cable (extension cable)
and replace if necessary.
Ground fault circuit interrupter
(GFCI) at the mains connec
tion (distributor) has triggered.
Shorten the connecting cable (extension ca
ble) between power socket and machine.
Put only one machine per ground fault circuit
interrupter into operation.
Batteries in the remote control
unit are empty. Radio connec
tion was interrupted.
Replace batteries in the remote control unit
(
!
Chapter 3.4.2 ‐ page 24).
Forward drive does not start. Coupling bolts [45, Fig. I] not
engaged completely.
Engage both coupling bolts
(
!
Chapter 3.4.1 ‐ page 24).
Battery charge indicator
[22, Fig. C] flashes red:
Drive battery is too weak.
Recharge drive battery for at least one hour
(
!
Chapter 3.5 ‐ page 26).
Remote control mode (wi
thout mains operation) was
interrupted.
Operation indicator light
[21, Fig. C] is no longer lit.
If no remote control signal is
received for 5 minutes, the re
mote control mode is swit
ched off automatically.
Move the switch [24, Fig. D] to the
Connec
tion scan setting.
New connection is established. Display
window:
RUN.
(
!
Chapter 3.4.3 ‐ page 24).
Machine reacts without con
trol.
Radio connection on the cur
rent channel is faulty.
Keep tapping the switch [24, Fig. D] to the
Menu side until a suitable channel is found.
Move the switch [24, Fig. D] to the
Connec
tion scan setting.
New connection is established. Display
window: RUN (
!
Chapter 3.4.3 ‐ page 24).