Maintenance
54
04.00 | SRU-plus-D | Assembly and Operating Manual | en | 1380765
8 Maintenance
8.1 Maintenance interval
CAUTION
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
•
Reduce the lubricant intervals accordingly.
Interval [Mio. cycles]
for
SRU-plus-D 20 - 60
Maintenance work
Daily
Visually inspect the function of the shock
absorbers
Interval [Mio. cycles]
for
SRU-plus-D 20 - 40
Maintenance work
2
Clean all parts thoroughly, check for damage
and wear, if necessary replace seals and
wearing parts,
2
Treat all grease areas with lubricant,
2
Check that the shock absorbers are working,
if necessary replace shock absorber
Interval [Mio. cycles]
for
SRU-plus-D 50 - 60
Maintenance work
1
Clean all parts thoroughly, check for damage
and wear, if necessary replace seals and
wearing parts,
1
Treat all grease areas with lubricant,
1
Check that the shock absorbers are working,
if necessary replace shock absorber