Basic safety notes
3.00 | PRH | Assembly and Operating Manual | en | 389327
9
2.4 Spare parts
Use of unauthorized spare parts
Using unauthorized spare parts can endanger personnel and
damage the product or cause it to malfunction.
• Use only original spare parts or spares authorized by SCHUNK.
2.5 Ambient conditions and operating conditions
Required ambient conditions and operating conditions
Incorrect ambient and operating conditions can make the product
unsafe, leading to the risk of serious injuries, considerable material
damage and/or a significant reduction to the product's life span.
• Make sure that the product is used only in the context of its
defined application parameters,
22].
2.5.1 Electromagnetic compatibility
The product meets the requirements of the EMC act of the inner-
European market, among other requirements. The product has
passed the EMC test as per the following standards:
Standard
Title
EN 61000-6-2 (2006)
EMC: Generic standard – Immunity for industrial
environments
EN 61000-6-3 (2011)
EMC: Generic standard – Emission standard for residential
and light-industrial environments
The product must be installed using interference-free cables and in
a way that meets EMC requirements in order to ensure
interference-free operation.
Interference
Pulse-shaped interference:
The following table shows the electromagnetic compatibility in
relation to pulse-shaped interference.
Pulse-shaped interference
Tested with
Corresponds
to degree of
severity
Electrostatic discharge as per
EN 61000-4-2 (2008)
Air discharge: 8 kV
Contact discharge: 4 kV
3
Burst pulses, fast transient
interference as per
EN 61000-4-4 (2008)
Supply line: + - 2 kV
On signal, data and control cable: + -
1kV
3
High-energy single pulse (surge)
EN 61000-4-5
+ - 500V, symmetrical surge,
+ - 500V, asymmetrical surge
(Cable length > 30 m)
1