Basic safety notes
10
3.00 | PRH | Assembly and Operating Manual | en | 389327
Sinusoidal interference:
The following table shows the electromagnetic compatibility in
relation to sinusoidal interference.
Sinusoidal interference
Test values
Corresponds
to degree of
severity
HF radiation
(electromagnetic fields) as per
EN 61000-4-3
80% amplitude modulation at
1 kHz to 10 V/m in the range of
80 … 1000 MHz to 3 V/m in the range
of 1.4 … 2 GHz to 1 V/m in the range of
2 … 2.7 GHz
3
HF energization on cables and cable
shielding as per
EN 61000-4-6
Test voltage 10 V with amplitude
modulation
80% of 1 kHz in the range of
150 kHz … 80 MHz
3
Emission of radio
interference
Emissions were tested and confirmed as per EN 61000-6-3.
Conducted interference emissions
Value
0.15 … 0.5 MHz
0.5 … 5 MHz
5 … 30 MHz
< 66 dB (µV) quasi-peak, < 56 dB (µV) average
< 56dB (µV) quasi-peak, < 46 dB (µV) average
< 60 dB (µV) quasi-peak, < 50 dB (µV) average
The following table shows the interference emission from
electromagnetic fields as per EN 55011:2009, limit class A, group 1,
measured at a distance of 10 m.
Interference
Value
30 … 230 MHz
230 … 1000MHz
< 30 dB (µV) quasi-peak, measured at 10m
< 37 dB (µV) quasi-peak, measured at 10m