Assembly and installation
3.00 | PRH | Assembly and Operating Manual | en | 389327
33
Pin allocation S3 (CAN bus input)
Pin
Designation
Function
SCHUNK cable
color
1
Shield
Shield
2
n.c.
-
3
CAN_GND
CAN_GND
yellow
4
CAN_H
CAN_H
white
5
CAN_L
CAN_L
brown
CAN assignment of 9-pin SUB D socket
SUB D socket solder side
Pin
Function
2
CAN_L
3
CAN_GND
7
CAN_H
Terminating a
module
The CAN bus terminator supplied can be used for termination.
Ø
Screw the CAN bus terminator on S2, if the module is the last
bus subscriber.
Combining several
modules
When combining several modules, the signals from module n are
looped through to module n+1. The wires from terminal X2 on
module n are connected to terminal X1 on module n+1.