Assembly and installation
3.00 | PRH | Assembly and Operating Manual | en | 389327
31
5.3 Electrical connection
NOTE
The cable color throughout this chapter refers to the use of a
SCHUNK connection cable.
NOTICE
Risk of damage to the electronics!
Regenerative energy may build up under great loads.
•
Ensure discharge of regenerative energy on customer's
premises. SCHUNK recommends using a brake chopper,
forexample Schneider Universal Braking Control UBC60;
ACC3EA001.
5.3.1 USB parameterization interface
The USB communication interface is not suitable due to its field
bus system characteristics. Only use the USB interface as a
parameterization interface.
The USB connection cable supplied or the optionally available
SCHUNK service box SSB is required, in order to connect the
module to a PC.
SCHUNK recommends using a USB isolator to protect the USB
communication interface of the host PC.