Maintenance
46
11.00 | GSM-P | Assembly and Operating Manual | en | 389104
GSM-P manufactured before 05/2019:
Assembly position is not marked on the socket.
1. Insert gripping module (2) into socket (4) and align so that the
dot marking of the gripping module points to the middle of the
semicircular side of the socket.
2. Using new screws (1) from the spare parts package, screw the
gripping module (2) firmly onto the socket (4).
Note: Observe max. tightening torque!
3. Secure all compressed air lines.
GSM-P manufactured after 05/2019:
Correct assembly position is marked on the socket.
1. Insert gripping module (2) into socket (4) and align so that the
arrow marking of the socket points to the dot marking of the
gripping module.
2. Using new screws (1) from the spare parts package, screw the
gripping module (2) firmly onto the socket (4).
Note: Observe max. tightening torque!
3. Secure all compressed air lines.
8.6.3 Mounting orientation of the magnets, item 120
Top view in rotating angle position for 0°-180° variants