![SCHUNK GSM-P 32 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/schunk/gsm-p-32/gsm-p-32_assembly-and-operating-manual_1215729027.webp)
Assembly
5.3.4 Switch-off hysteresis for magnetic switch MMS-P 22
The smallest detectable difference in stroke is defined in the
following table:
The smallest detectable difference in stroke based on the nominal stroke
For grippers with X mm
nominal stroke per jaw
Min. query range per jaw/
min. queried stroke difference per jaw
X ≤ 5 mm
60% of the nominal stroke per jaw
X > 5 mm to X ≤ 10 mm
40% of the nominal stroke per jaw
X > 10 mm
20% of the nominal stroke per jaw
Example:
Product with 7 mm nominal stroke per jaw
7 mm * 40% = 2.8 mm
NOTE
The table of values applies only to sensors whose hysteresis has
been taught. For further information see assembly and operating
manual of the sensor.
5.3.5 Assembly and setup of the MMS-P 22
Position and installation of the MMS-P magnetic switches
27
11.00 | GSM-P | Assembly and Operating Manual | en | 389104