Design and description
04.00 - FW 2.x | EGL | Assembly and Operating Manual | en | 389661
25
If a device is connected to one or both USB interfaces, the
respective bus connection will not function even if a bus cable is
connected.
In the following cases, communication via the bus connection is
not possible:
• If a USB device is connected to the interface USB mini AB,
device.
• When connecting the USB stick to the interface USB micro AB,
host and when the DIP switch 1 is "ON".