Assembly and Operating Manual
AGE-F-XY
– Compensation Unit with spring return
9
Date printed 28.12.2009
6
Troubleshooting
Event
Possible cause
Possible solution
Module does not move
Set screw/stop screw screwed in
too deep
Use a shorter stop screw (see chapter
5.3, page 8)
Solenoid switch (MMS-P)
does not work / cannot be
adjusted
Steel screws used for fastening
the compensation unit.
Replace steel screws with VA screws
Mounting plates, angle brackets
etc. from magnetizable materials
Check, replace with nonmagnetizable
parts
– perhaps use aluminum or
plastic
Tabelle 5