![SCHUNK 1487754 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/schunk/1487754/1487754_assembly-and-operating-manual_1215863029.webp)
Troubleshooting
9 Troubleshooting
9.1 Safety
Maintenance work may only be carried out by qualified personnel.
WARNING
Risk of injury due to incorrect maintenance or troubleshooting
•
Check the proper functioning of the product, especially the
safety features, after every maintenance or troubleshooting
operation.
CAUTION
Improper installation or maintenance
Personal injury or damage to property
•
Prior to installation and before maintenance work, the
product must be disconnected from the power supply,
depressurized (vented to the atmosphere) and secured
against unauthorized restart.
9.2 Faults, Causes, Solutions
Fault
Possible cause
Solution
The workpiece is
not picked up or
the vacuum does
not build up.
The sealing gasket is not forming a
seal between the workpiece and
the Matrix-Plate.
Insert the sealing gasket in the slot
as described in section 7.3.4 (a
sealing gasket with a different
diameter may be required).
The workpiece is curved and does
not lie flat on the Matrix-Plate.
Press down on the workpiece so
that the sealing gasket forms a seal
and a vacuum is created. Once the
vacuum has built up, the workpiece
will automatically lie flat against
the Matrix-Plate.
There is no open vacuum vent
within the vacuum area bordered
by the sealing gasket.
Open at least one vacuum vent
within the vacuum area enclosed
by the sealing gasket. If there are
no vacuum vents within the
enclosed area, the sealing gasket
must be moved to a different
position on the SMPL.
There is no vacuum at the Matrix-
Plate.
Check the vacuum supply. If
necessary, activate the vacuum
generator, open the valves and
check the hose line.
29
01 | Matrix-Plate SMPL | Assembly- and Operating Manual | en-US | 0489081
Содержание 1487754
Страница 1: ...Translation of the original manual Assembly and Operating Manual Matrix Plate SMPL ...
Страница 38: ......