Start of Operations
If an open vacuum vent is outside the mapped workpiece contour,
the required vacuum will not be reached. The workpiece may
become loose during processing or will not be clamped at all.
• To ensure the vacuum supply, at least one vacuum vent must be
located within the workpiece contour.
• There must be no open vacuum vents outside the workpiece
contour.
• Unused vacuum vents must be closed with the corresponding
plugs.
The operating vacuum can now be activated. The workpiece may
need to be pressed slightly onto the Matrix-Plate until the
operating vacuum has been established.
7.3.5 Checking the System for Leaks
The supplied gauge must be used to check whether the intended
operating vacuum is reached.
The SCHUNK vacuum units designed for operation of the Matrix-
Plates support the monitoring process with audible and electronic
warning devices.