![SCHUNK 1487754 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/schunk/1487754/1487754_assembly-and-operating-manual_1215863015.webp)
Installation
6 Installation
6.1 Installation Instructions
The preferred installation position for the Matrix-Plate is
horizontal on the machine table of a machining center.
NOTE
If a different installation position is selected or if the installation
position changes (for example, in the case of swiveling machine
tables), gravity also acts against the clamping force.
If the vacuum drops, there is a risk that the workpiece will fall.
Note:
If you wish to connect several Matrix-Plates, first consult chapter
6.4 (“Connecting Several Matrix-Plates”).
6.2 Mechanical Attachment
In principle, the Matrix-Plate can be adapted to any of the
following machine table variants:
• Machine table with T-slots
• Machine table with vises
• Machine table with zero point clamping system
Preparation
• Clean the machine table (remove chips, cooling lubricant
residue).
• Connect the hose connection kit to the Matrix-Plate.
– In the case of a machine table with a zero point clamping
system, the hose connection kit must be attached to the
underside of the Matrix-Plate.
– In the case of a machine table with T-slots or with vises, the
distributor of the hose connection kit must be attached
separately to the machine table.
• Position and align the Matrix-Plate on the machine table.
• Connect the gauge connection kit to the Matrix-Plate and attach
the gauge at an appropriate position in/on the machine so that
it can be read easily.
Mounting on the machine table
• Mounting using clamping claws
Use the side grooves in the Matrix-Plate.