![Schmalz FMHD Series Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/schmalz/fmhd-series/fmhd-series_operating-instructions-manual_1212859042.webp)
42 | EN
www.schmalz.com
30.30.01.01648/03
4. If it is heavily contaminated, the
valve plate
must also be cleaned. To do so, first unscrew the
screws in the end covers (A+F) by a few millimeters so that the valve plate and the sealing does
not damage the front sealing when you remove the valve plate.
5. Next, unscrew the screws of the valve plate (5). Start with the outer screws. The screws are se-
cured against falling out with small sleeves (item no. 16 on the spare parts list). Ensure that the
valve plate does not fall during disassembly.
6. To clean the valves, carry out the following steps:
Remove the adhered masking film (H).
If the masking film is still in very good condition, it can be reused
– the adhesive surface must
be protected against dust/moisture.
Remove the spherical bearings, e.g. using a magnet (6.1).
Soak the contaminated bearings in a soap/detergent solution.
Blow out the valve section (G)/valves (without sliders) with compressed air or, if necessary,
clean them with solvents (soak if necessary).
Dry all of the parts.
Insert the sliders/spheres back into the valves. Insert one slider into each valve to ensure that
the valves work properly.
Reattach the masking film. Ensure that the openings of the clover shapes align with the valves.
Clean the base profile if necessary (see point 7).
Note the asymmetry of the valve plate and screw it back on to the base profile (D). To assemble
the parts, carry out the steps for disassembly in the reverse order. Tightening torque of the
screws: 10 Nm. The base and valve profiles must be flush to one another and may not be shift-
ed relative to one another.
In the final step, screw the end cover on tightly, suspend the quick-change section and clamp it
tightly. Tightening torque of the screws: 10 Nm.
4
5
6
4
6.1
A
F