Check the sealing mats for wear, tears and leaks. Re-
place if necessary.
X
General condition of the device
X
Leak Test
X
Check the storage/suction chambers and ball valves for
dirt
They may only be cleaned by trained and instructed
specialist personnel/the manufacturer
– see chapter 9.9
The interval depends on the applica-
tion/ambient conditions.
We recommend checking the contamina-
tion within the suction bar for the first time
in the first month after start of operations.
External Vacuum Generator
8.3
See the relevant operating instructions.
Dust Filter
8.4
When using a dust filter, see the relevant operating instructions.
Cleaning Agents
8.5
Use cleaning solvents to clean the device (not petroleum ether or corrosive liquids. Petroleum ether or
corrosive liquids destroy the vacuum hoses).
Quick-change Plate
8.6
To make maintenance easier and replace the foam more quickly, the quick-change sealing plate is inte-
grated into the gripper as standard. In order to reduce downtime, a second, identical plate can be made
available during maintenance and used to replace the contaminated plate. See chapter 9.9