Component Functions
EN-US · 30.30.01.02237 · 00 · 04/20
45 / 94
The functions relate to an ejector SCTSi and apply to each individual ejector, regardless of the number of
installed ejectors.
IO-Link Master Functions
•
Process data management (IO-Link device process data is copied to the Ethernet process data)
•
Port configuration
•
IO-Link ISDU – data management (read/write parameter data of IO-Link devices)
•
IO-Link event handling
DI Module Functions
•
Process data management (input status is copied to the Ethernet process data)
Note about replacing the device: All modifiable parameter data (e.g. switching point settings)
is saved in the bus module. When replacing an ejector, the previous data is loaded to the new
ejector.
6.2 Bus Module Functions
6.2.1 System Commands (0x0002)
System commands are predefined processes to trigger specific functions. They are controlled by writing
parameter 0x0002 with a predefined value.
Offset parame-
ter
2 (0x0002)
Description
System command – triggers special features of the device
Index
-
Data type
uint8
Length
1 bytes
Access
Write only
Value range
0x82: Reset device parameters to factory defaults
0xA5: Calibrate vacuum sensors of all ejectors
0xA7: Reset erasable counters in all ejectors
0xA8: Reset voltage min./max.
Default value
-
Unit
-
EEPROM
no
Reset to Factory Settings
This function is used to reset all settings parameters for the ejector to the factory settings.
The “0x82” system command is used to reset all settings parameters for the ejectors to the factory set-
tings.
Counter statuses, the zero-point adjustment of the sensor and the maximum and minimum values of the
measurements are not affected by this function.
Zero-Point Adjustment (Calibration)
Since the sensors installed in the ejectors are subject to variants based on the manufacturing process, it is
recommended to calibrate the sensors in the application environment in which the Compact terminal
SCTSi will be used.