Component Functions
52 / 94
EN-US · 30.30.01.02237 · 00 · 04/20
16: 0 … 1048560
Default value
-
Unit
0.1 Nl
EEPROM
no
Measure Leakage (0x00A0)
This function measures the leakage (represented as the vacuum drop per time unit in mbar/s) after the air
saving function interrupts the suction because switching point H1 was reached.
Offset parame-
ter
160 (0x00A0)
Description
Leakage rate for ejectors
Index
Index 0 to 15 corresponds to ejector #1 to #16
Data type
uint16
Length
32 bytes
Access
Read only
Value range
0 … 8000
Default value
-
Unit
mbar/s
EEPROM
no
Measure Dynamic Pressure (0x00A1)
This measures the system vacuum achieved during unobstructed suction (free flow vacuum). The duration
of the measurement is approx. 1 second. Therefore, to evaluate a valid dynamic pressure, uninterrupted
suction is required for at least 1 second after starting the suction, i.e. the suction point must not be cov-
ered by a part.
Measured values below 5 mbar or above the switching point H1 are not regarded as valid dynamic pres-
sure measurements and are rejected. The result of the last valid measurement is retained.
Measured values above the switching point (H2 - h2) but simultaneously lower than switching point H1
result in a condition monitoring event.
Offset parame-
ter
161 (0x00A1)
Description
Free-flow vacuum for ejectors
Index
Index 0 to 15 corresponds to ejector #1 to #16
Data type
uint16
Length
32 bytes
Access
Read only
Value range
0 … 999
Default value
-
Unit
mbar
EEPROM
no
Maximum Vacuum Reached (0x00A4)
In each suction cycle, the maximum system vacuum level reached is determined and made available as a
parameter.
Offset parame-
ter
164 (0x00A4)
Description
Max. vacuum reached in cycle for ejector
Index
Index 0 to 15 corresponds to ejector #1 to #16