The information in the table below refers to the IO-Link master 1 Port X1. For additional IO-Link masters
or ports, the following offset addresses must be added:
Offset for Additional Ports (Dec)
Port X1
Port X2
Port X3
Port X4
IO-Link master 1
+ 0
+ 6
+ 12
+ 18
IO-Link master 2
+ 24
+ 30
+ 36
+ 42
Example: “Event Instance” has the following addresses at the corresponding ports (Dec)
Port X1
Port X2
Port X3
Port X4
IO-Link master 1
10605
10611
10617
10623
IO-Link master 2
10629
10635
10641
10647
“Parameters – IO-Link Master: Events”
Offset
Description
Type
Length
[bytes]
R/W
(Dec)
(Hex)
10605
0x296D
Event-Instance
uint8
1
ro
10606
0x296E
Event-Mode
uint8
1
ro
10607
0x296F
Event-Type
uint8
1
ro
10608
0x2970
Event-Origin
uint8
1
ro
10609
0x2971
Event-Code
uint8
1
ro
10610
0x2972
Event-Number
uint8
1
ro
Parameters – IO-Link Master: Device Process Data
Offset
Index
Description
Type
Length
[bytes]
R/W
(Dec)
(Hex)
10600
0x2968
—
Master 1 process data input
uint8
128
R
10601
0x2969
—
Master 2 process data input
uint8
128
R
10602
0x296A
—
Master 1 process data output
uint8
128
RW
10603
0x296B
—
Master 2 process data output
uint8
128
RW
Parameters – IO-Link Master: ISDU Parameter Management
The information in the table below refers to the IO-Link master 1 Port X1. For additional IO-Link masters
or ports, the following offset addresses must be added:
Offset for Additional Ports (Dec)
Port X1
Port X2
Port X3
Port X4
IO-Link master 1
+ 0
+ 20
+ 40
+ 60
IO-Link master 2
+ 100
+ 120
+ 140
+ 160
Example: “Request: Index” has the following addresses at the corresponding ports (Dec)
Port X1
Port X2
Port X3
Port X4
IO-Link master 1
10200
10220
10240
10260
IO-Link master 2
10300
10320
10340
10360