3 / EN
EN· 30.30.01.02952 · 00 · 07/21
1
Main body
2
Sliding block strips
3
Insert element for optimizing the flow
4
Valve film
5
Sealing plate
6
Ejector assembly FXP-i (functional unit)
7
Silencer FXP-i
8
Valve assembly FMP-i (functional unit)
9
Suction cup connection strip with suction
cups
10
Hose connector FMP-i
11
End cover
12
Balls for SVK technology (not for SW)
2.2
Connections
1
Compressed air connection
2
M8 electrical connection, 6-pole
3
NFC area
4
Connection for separation function
5
Mounting holes for pentaprism
6
Marking
2.3
Electrical Parameters
Supply voltage
DC 24 V ± 10% (PELV
1)
)
Polarity reversal
protection
yes
Current consumption
(at 24 V)
-
Typical current
consumption
Max. current
consumption
FXP-i – xx – NC
50 mA
70 mA
FMP-i – xx – NO
75 mA
115 mA
NFC
NFC Forum Tag type 4
IO-Link
IO-Link 1.1 Baud rate COM2 (38.4 Kbits/s)
1)
The power supply must correspond to the regulations in accordance with EN60204 (protected extra-low voltage).
2.4
Mechanical data
2
5
4
1
3
6