OPERATOR'S MANUAL
LuchsNT
Version: 27142-A.1
Subject to technical changes
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
9
Position 7 is unassigned.
Position 8 defines the termination of the DMX bus.
Function Pos.8
Note
DMX terminating resistor
active
ON
Device identified as BUS terminal device
DMX terminating resistor
inactive
OFF
3.6 "Analog"
control
terminal
Used to control the light intensity.
The control function is always active for the LED-white control unit
Or for the RGB control unit in operating mode
Analog
Piezo
The standard signal input 0...10V has the following connection terminals:
10V
Power supply voltage for potentiometer
IN
Signal input
GND
Note:
Min. potentiometer resistance value 1 k
-
typically 100 k
(optional accessories)
A defined signal must be present at signal
input IN.
Delivery condition: Wire jumper between IN
and 10V
3.7
"DMX" control terminal
+
Line "A" or "+"
–
Line "B" or „–“
GND / shield
DMX signal display
LED
If the LED lights up, a DMX signal is
present at the input
Note:
The interface is electrically isolated
For the bus installation, shielded cables twisted in pairs must be used. E.g. CAT6
network cable
Ensure that the polarity of the bus connection is correct