OPERATOR'S MANUAL
LuchsNT
Version: 27142-A.1
Subject to technical changes
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
17
Configuration
Control unit setting:
Position 6:
ON
Position 3:
ON
Function: BUS Master
Function: Button
Converter box 3.0 setting
Rotary switch: MODE A
Requirement: SW 0.23 or higher
BUS
LED
The communication between converter box and switch box is active when
the yellow BUS-LED in the converter box lights up.
POWER
LED
The 24V operating voltage is applied in the converter box when the red
POWER LED lights up. The converter box is ready for operation.
The LuchsNT LED control unit is connected to the converter box via a 4-wire cable.
BUS: two wires, any polarity.
Power supply voltage: two wires
If the converter box is connected with mode A, no further bus subscribers can be
connected.
External buttons via the converter box can also be connected in the synchronous mode
of several control units. The connection is made to the SYNC-MASTER device.