5
2 Functional
features
2.1
LuchsNT RGB control unit interface
DMX interface colour light control
0-10V analog interface light
intensity control 0-100 %
6 fixed colours
1 fixed colour gradient
Synchronisation bus for synchronous control of several control units
Control bus for optional functional enhancement
2.2
LuchsNT LED control unit interface
0-10V analog interface light
intensity control 0-100 %
Synchronisation bus for synchronous control of several control units
Control bus for optional functional enhancement
2.3
Functional sequence after mains voltage ON
The system (control unit + spotlights) boots.
The system is ready for operation after 2 seconds.
This means that after 2 seconds
the spotlights are lit, depending on activation and assignment of the interface.
2.4
Switching the spotlights ON / OFF
via START / STOP input
The input can be set to latching or momentarily via DIP switch 3
Delivery condition: latching with bridge
The connected buttons and switches must be potential-free
For a detailed functional description, see section 3.4
If the spotlights are OFF via the STOP input or control input Analog IN=0V or DMX
control input, this is detected by the device and after 60 seconds the output terminals
LED + and LED – are disconnected via a relay. If the spotlights are switched ON, a relay
switches the voltage back to the output terminal.