LuchsNT 

Version: 27142-A.1

 

7 Technical 

data 

7.1 Technical 

specification 

Dimensions 

max. W x H x D (in mm) 

Weight 

205 x 130 x 270 
approx. 3.2 kg 

Mains input

 (L, N, PE) 

Nominal voltage U

in

 

Input voltage range U

Nominal input current I

N max.

 

 

Standby power /standby losses

 

 

 

230 V AC, 50 Hz 1~ 

100 … 264 V AC 50/60 Hz 

1.5 A for 230 V AC or 2.2 A for 115 V AC 

5 W

 

Output

 (0 V, 24 V) 

Nominal voltage U

out

 

Output current I

out max.

 

Efficiency type

 

 

 

24 V DC SELV 

 

5.5 A / 8.5 A 
90 %

Protection and monitoring 

Mains input fuse F1 
Current limitation 
Overload-proof 
Open-circuit proof 
Excess temperature

 

 
T1.6 (250V) 
continuously short-circuit proof 
yes 
yes 
Power derating 

T

amb

> 50°C 

Shut-off  

T

amb

> 70°C 

Safety

 

Output: 
Protection class 

VDE 0805/EN60950/IEC950 
Safety extra-low voltage SELV 
Class I

EMC 

 

EN55011 
EN61000-6-1

Ambient temperature

 

Operation 
Storage 

 
-30°C to +50

-40

C to 70

Degree of protection 

IP65 

Only if unused cable screw 
connections are sealed with plugs

Mains / LED connection terminals 

Rigid cable cross-section 
Flexible cable cross-section  

with

 ferrule 

 
max. 4.0 mm² 
 
max. 2.5 mm²

Feedback /control contact connection terminals

Rigid cable cross-section 
Flexible cable cross-section  

with

 ferrule 

0.5 … 1.5 mm² 
 
0.5 … 1.0 mm² 

Piezo button 

Voltage on button and LED 
Switching threshold for button 
LED current 

 
22.5 … 25.5 V DC 
10 … 14 V DC 
max. 30m A DC 

Display 

LED – GREEN 
LED - RED 

Operation 
Service 

 

 
 

Содержание fluvo LuchsNT

Страница 1: ...LuchsNT RGB LED Operator s Manual Translation of the original 27142 A 1 GB ...

Страница 2: ... Configuration via DIP switch 8 3 6 Analog control terminal 9 3 7 DMX control terminal 9 3 8 BUS control terminal 10 3 9 DIAG system diagnosis button 11 3 10 Sensor button connection diagram 12 4 Functional Description 13 4 1 Operating mode 13 4 2 LED display 14 4 3 Synchronisation of several LED control units 14 4 4 Individual control of the RGB spotlights 15 4 5 Colour light control with custome...

Страница 3: ...ety and to protect the product please read the Operator s Manual carefully before starting with the installation and settings All persons involved in setting up commissioning operating maintaining and repairing this device must be appropriately qualified meticulously observe the operator s manual consider the operator s manual to be part of the product keep the operator s manual in a safe place th...

Страница 4: ... Before beginning installation and service work the power supply connection must be switched off The device does not contain any components that require servicing by the user The housing cover may only be opened by the manufacturer guarantee seal In the event of a malfunction we recommend contacting the supplier Attention Failure to observe the safety instructions for example touching live parts w...

Страница 5: ...hancement 2 3 Functional sequence after mains voltage ON The system control unit spotlights boots The system is ready for operation after 2 seconds This means that after 2 seconds the spotlights are lit depending on activation and assignment of the interface 2 4 Switching the spotlights ON OFF via START STOP input The input can be set to latching or momentarily via DIP switch 3 Delivery condition ...

Страница 6: ...C OUT Bus control unit synchronisation output 4 BUS Manchester bus interface 5 DMX PWR DMX 24V power supply for i light 6 DMX IN DMX input for series operation 7 SYNC IN Control unit synchronisation input 8 LED RGB lighting START STOP piezo button 9 START STOP Sensor button input on off 10 COLOR Sensor button input colour selection 11 DIAG Button and 2 LEDs for diagnostic purposes 12 ADDR Manchest...

Страница 7: ...emoved for easier wiring as follows Terminal compartment disconnection Installation is in the opposite order 3 3 Mains power connection The L N PE connection of the power supply voltage must be made in accordance with VDE 0100 and VDE 0160 A protective and isolating device must be provided for turning off the power supply Terminal PE must always be connected to a protective ground Screw terminal w...

Страница 8: ...alog function is always active regardless of position 1 and 2 Position 3 determines whether input 9 START STOP is to be used for a button or a latching switch Function Pos 3 Note Button ON the device switches for each signal pulse latching switch OFF the device is switched as long as the signal is present Position 4 determines whether a single colour or an RGB button is connected to input 8 LED Fu...

Страница 9: ...rol unit in operating mode Analog Piezo The standard signal input 0 10V has the following connection terminals 10V Power supply voltage for potentiometer IN Signal input GND Note Min potentiometer resistance value 1 k typically 100 k optional accessories A defined signal must be present at signal input IN Delivery condition Wire jumper between IN and 10V 3 7 DMX control terminal Line A or Line B o...

Страница 10: ...6 151 166 181 196 211 Note on switch position 0 Variable only on request DMX start address 1 default setting 3 7 2 DMX Individual control of the LED spotlights This is optionally available on request Not included in the standard version 3 8 BUS control terminal A Line A B Line B DMX signal display LED If the LED lights up a BUS signal is present Interface for operation via BUS for connecting optio...

Страница 11: ...he end of the diagnosis by pressing the button again 3 9 1 Basic diagnosis The basic diagnosis includes the following procedure After the start of the diagnosis connected spotlights are searched for The diagnostic LED 1 flashes during the spotlights search After completion of the search diagnostic LED 1 lights up permanently diagnostic LED 2 flashes indicating the number of spotlights found In add...

Страница 12: ... in the picture on the left The switching operation is reported back For the RGB control unit an RGB button can be optionally connected which visually reports back the spotlights colours In order to control the Piezo function of fixed colours and colour gradients an additional sensor button must be connected to the COLOR input The keying pulses at the COLOR input are used to switch between the ind...

Страница 13: ... are enabled via the START STOP input according to the setting on dip switch 3 latching momentarily The program is selected via the keying pulse at the COLOR input The following programs are stored Program 1 2 3 4 5 6 7 Colour Turquoise Red Yellow Green Light blue Dark blue Colour gradient For the colour gradient the colours are selected in sequence 1 6 one after the other The idle time per colour...

Страница 14: ...on of several LED control units The synchronisation bus is available for the operation of several control units with the same control signal A device is operated as a MASTER to which the control signals are connected The remaining devices are operated as SLAVE The MASTER OFF SLAVE ON setting is configured via pos 5 A SLAVE device uses only the brightness information from the synchronisation bus Ea...

Страница 15: ...r specific DMX control unit The coloured light can be controlled via a customer specific DMX control unit e g central house control Several different DMX receivers e g pool lighting room and hall lighting can be connected to each other via the DMX bus The termination of the DMX bus terminating resistor must be set correctly Whether a signal is present at the DMX IN input terminal is visible via th...

Страница 16: ...give visual feedback provided they are illuminated The button lighting lights up when the spotlights are ON and light up It is unlit when spotlights are OFF The LEDs go out during the blocking time In the connected converter box the LED display and digital outputs DOUT1 to DOUT3 show the following status of the switch box DOUT4 is switched when spotlights are switched on The status of the digital ...

Страница 17: ... the yellow BUS LED in the converter box lights up POWER LED The 24V operating voltage is applied in the converter box when the red POWER LED lights up The converter box is ready for operation The LuchsNT LED control unit is connected to the converter box via a 4 wire cable BUS two wires any polarity Power supply voltage two wires If the converter box is connected with mode A no further bus subscr...

Страница 18: ...onnection cable type of installation are the same for LED white and RGB Connection cable 2 wire sheathed cable Standard length 3 m other lengths on request Cable outer diameter ø 5 80 mm Wire cross section 1 5 mm AWG24 Colour code of cable wires red Power supply voltage VCC black Power supply voltage GND Maximum electrical power per spotlights 33 W The spotlights must only be operated under water ...

Страница 19: ...E 0100 520 Wiring Systems electromagnetic interference must also be taken into account In order to avoid interference observe the specifications for communication cabling according to DIN EN 50173 and DIN EN 50174 VDE 0800 174 The maximum cable length between spotlights and LED control unit is 30m Pay attention to the cable cross section 6 2 Spotlights LED control unit connecting cable Applies to ...

Страница 20: ...oof Open circuit proof Excess temperature T1 6 250V continuously short circuit proof yes yes Power derating Tamb 50 C Shut off Tamb 70 C Safety Output Protection class VDE 0805 EN60950 IEC950 Safety extra low voltage SELV Class I EMC EN55011 EN61000 6 1 Ambient temperature Operation Storage 30 C to 50 C 40 C to 70 C Degree of protection IP65 Only if unused cable screw connections are sealed with p...

Страница 21: ... 72072 Tübingen Germany 21 7 2 Dimensions Dimensions in mm Terminal compartment Guarantee seal Type plate Type plate Power Service Cable screw connector Spotlights supply line 2x cable ø 6 mm 6x cable screw connector Control line Cable ø 3 5 7 mm Cable screw connector Mains supply line Cable ø 7 13 mm ...

Страница 22: ...nting space Mounting position Wall mounted It is crucial to observe the proper installation position in order to ensure optimum cooling A clearance of at least 50 mm must be maintained below and above the power supply The air intake temperature at the underside of the device must not exceed the values given in the technical data Optional accessories Adapter plate for DIN rail mounting Front Air in...

Страница 23: ...rent Luft T max ambient temperature Pout max output power Uout output voltage Iout max output current HW Hardware version SW Software firmware version SN Serial number 7 5 Guarantee seal For position of guarantee seal see section 7 2 If the guarantee seal is destroyed the guarantee and manufacturer s warranty shall be rendered null and void All setting options are located in the freely accessible ...

Страница 24: ...gstechnologie Im Schelmen 9 11 D 72072 Tübingen Germany Phone Fax Internet E mail 49 0 7071 70 08 0 49 0 7071 70 08 14 www fluvo de info schmalenberger de 2019 Schmalenberger GmbH Co KG All rights reserved Manual is subject to changes ...

Отзывы: