27
Pump NB/FB/WP/SM/F
Version: 27216 - E
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
5.2
Disposal
If you want to shut down the pump permanently and take it out of operation, observe local
regulations for disposal of industrial waste.
The cleaning agents and remaining pumping medium must also be handled according to
legal requirements.
If legal requirements in the pump operator's area so stipulate, the pump must be broken
down and separated into different materials which must then be disposed of separately.
5.3
Documents for the pump drive
The following documents created by the motor manufacturer are enclosed:
•
Operator’s Manual
•
Dimensional diagram
For complaints related to the pump motor, please contact us or the motor manufacturer.
Special features of mechanical seals:
Before initial commissioning and after an extended down time, or after
installation of a new mechanical seal, always check for smooth operation.
Due to adhesive forces, the slide ring and counter ring may cling together
strongly. When this happens, the driving spring does not have sufficient
traction to break the slide ring free. Then the shaft runs into the fixed seals and
driving spring, which results in damage. Remove the fan hood and rotate the
fan wheel in the direction of the arrow indicating direction of rotation. If you
encounter resistance and the fan wheel springs back, the mechanical seal
must be removed and the slide and counter rings must be carefully separated.
Try not to rotate the shaft forcefully.
Danger of death / danger of poisoning!
Pumps that have pumped toxic, corrosive or other chemical substances which
represent a hazard to people and animals must be thoroughly cleaned and/or
decontaminated before disposal.