21
Pump NB/FB/WP/SM/F
Version: 27216 - E
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
4.2.2
Disassembly / Removal of the Pump
The pump must have reached ambient temperature.
•
Disconnect the power supply.
•
Close the fittings (suction and pressure-end).
•
Empty the pump through the drain screws 912, 913.
•
If the system has a catchment chamber / pressure chamber, empty it through the drain
screws 912. Dispose of the sealing medium properly.
•
Unclamp the motor.
•
Disassemble any additional connections that are present.
•
Loosen the pressure and suction connections.
•
Loosen the pump from the base plate.
•
Lift the pump out completely.
4.2.3
Disassembly / Dismantling the Pump
Before beginning
Do not begin working until you have checked to ensure:
•
that all necessary spare parts are present and they match the pump or the version of
the pump you have, or that damaged parts which may still be discovered can be
obtained in short order.
•
that you have all tools and auxiliary equipment required for work.
When
emptying
the pump observe the following instructions!
1. If the pump has been used with liquids that endanger health, make certain
when emptying the pump that there is no danger for persons or the
environment.
2. Wear protective clothing and a safety mask to the extent necessary!
3. The rinsing and residual liquid in the pump must be disposed of properly
without endangering persons or the environment.
4. Pumps which pump liquids that endanger health must be decontaminated.
When draining the pumping medium, make certain that there is no danger
for persons or the environment.
5. Legal requirements must be strictly observed.
Use only original spare parts for repairs!
Observing these instructions is a precondition for problem-free operation of the
pump and for honouring any warranty claims that may be submitted.
Customer Service:
Schmalenberger offers a 24-hour service for spare parts
delivery!