9 • Schlage • CT5000 user guide
Credential readers
An input device with either Wiegand (Data1/Data0) or Magnetic (Clock and Data) bit stream
can be used with the CT5000. The CT5000 provides two (2) separate credential reader
interfaces for control of one (1) opening.
The following readers are UL294 listed for use with the CT5000:
• Essex Electronics model KTP-162
• Mercury Security models MR-5 and MR-20, and XceedID models XF-1050, XF-1100,
XF-1500, XF-1550 and XF-2100
The following readers are ULCS319 listed for use with the CT5000:
• XceedID models PR10, SM10, MT11, MT11-485, MT15, MT15-485, MTK15 and MTK15-485.
Connect the shield of the reader 1 cable to the CT5000 J17-3 terminal (GND). Connect the
shield of the reader 2 cable to the CT5000 J18-3 terminal (GND). Do not connect the cable
shield at the credential reader.
L
Reader input ports are designed for 5V logic. Any voltage greater than 5V may
cause damage to either the CT5000 or the reader(s).
The CT5000 does not provide power to the reader(s). Power must be provided to the
reader(s) separately by a UL listed power supply. Refer to
Wiring Diagram
examples
on page 10, page 11, and page 12.
The CT5000 may not provide complete control of the reader’s beeper or LEDs. Please
consult the reader’s manufacturer for instruction on reader configuration.
Make sure your reader is configured with the LEDs and beeper OFF for best
compatibility.
Reader 1
terminal
Reader 2
terminal
Description
CLK/D1
J17-1
J18-1
Credential reader inputs: Each input line is pulled to
GND through a 12V transient suppressor and a 2 mega-
ohm resistor.
Wiegand or magnetic format is automatically detected.
DATA/D0
J17-2
J18-2
GND
J17-3
J18-3
The signal ground of the CT5000 must be tied to the
signal ground at the reader.
BEEPER
J17-4
J18-4
Beeper signal line connection to the reader.
This is an “open collector” style output, and has a 12V
transient suppressor to GND.
The output is switched to GND through a 100 ohm
resistor to activate the beeper on the reader.
Note: Most readers beep independently, and beeper
performance depends on the specific reader model.
GRN
J17-5
J18-5
Green LED signal line connection to the reader.
This is an “open collector” style output, and has a 12V
transient suppressor to GND.
The output is switched to GND through a 100 ohm
resistor to activate the green LED on the reader.
RED
J17-6
J18-6
Red LED signal line connection to the reader.
This is an “Open Collector” style output, and has a 12V
transient suppressor to GND.
The output is switched to GND through a 100 Ohm
resistor to activate the red LED on the reader.