15 • Schlage • CT5000 user guide
Construction access mode
Construction access mode is used to allow access before
the CT5000 controller has been programmed, and for testing
purposes.
• Enabled by default.
• The CT5000 controller will remain in construction access
mode until the mode is cancelled as described below.
• No audits are captured while the CT5000 controller is in
construction access mode.
CT5000 controller with readers
1. Remove the CT5000 lid.
2. Press and hold the Schlage button.
3. Present a credential to the reader within 5 seconds of
pressing the Schlage button.
4. The DEBUG LED and the reader’s LED will blink green
five (5) times.
5. This credential becomes the master construction
credential.
L
If the credential is not presented within 5 seconds,
timeout will occur. Repeat steps 2-5 above.
To program construction access mode user credentials:
L
The master construction credential must be
programmed before programming construction
access mode user credentials.
1. Present the master construction credential to the reader.
2. The DEBUG LED and the reader’s LED will light green
for 20 seconds.
3. Present the credential to be programmed within 20 seconds.
4. The DEBUG LED and the reader’s LED will blink green five (5) times.
Cancel construction access mode
Do one of the following:
• Program the lock with the HHD. See the SUS User Guide for more information.
• Reset the lock to factory settings. See
Reset to factory defaults
on page 15 for
information.
When construction mode is cancelled, the master construction credential and all other
credentials added using the master construction credential will no longer function.
Reset to factory defaults
All information in the CT5000 will be deleted and reset to factory defaults!
1. Remove the CT5000 lid.
2. Press and hold both the SCHLAGE and LINK buttons for approximately three (3)
seconds.
3. When the POWER/TAMPER LED turns off, release the buttons.
4. After a 15 second delay, the CT5000 DEBUG LED and the reader’s LED will blink
green for one second, and the reader will beep for one second.
5. Replace the lid.
TIPS
Use the same master
construction credential for
all the controllers in the
facility.
If you present the
first card with a new
controller to create the
master construction
credential and the card
is not accepted, the
controller has either been
programmed or already
has a master construction
credential.
If the master construction
credential cannot be
located, or to put the
controller back into
construction access
mode, reset the controller
to factory settings.
See
Reset To Factory
Defaults
below for more
information.