23 • Schlage • CT5000 user guide
CT5000 LED reference
LE
D
Co
nd
it
io
n
CT500
0
STRIKE (LED4
)
So
lid
G
REE
N
Re
la
y
en
er
gi
ze
d
O
FF
Re
la
y
de
-e
ne
rg
iz
ed
A
U
X
(LED5
)
So
lid
G
REE
N
Re
la
y
en
er
gi
ze
d
O
FF
Re
la
y
de
-e
ne
rg
iz
ed
A
LARM (LED6
)
O
FF
Re
la
y
de
-e
ne
rg
iz
ed
So
lid
G
REE
N
Re
la
y
en
er
gi
ze
d
Po
w
er
/T
am
pe
r
(LED7)
So
lid
G
REE
N
Co
ve
r o
n
Sl
ow
G
REE
N
fl
as
hing
Co
ve
r o
ff
U
SB
(L
ED
2)
A
lte
rn
at
in
g
RE
D
/G
REE
N
SU
S
coupl
in
g
Sl
ow
G
REE
N
fl
as
hing
U
SB
c
onn
ec
te
d
Not
e: L
oca
tions of objec
ts and scale
of diag
ram ar
e appr
oxima
te
.
NO
TE:
This inf
or
ma
tion per
tains ONL
Y
to the C
T5000 c
on
tr
oller devic
e.
If this C
T5000 is changed t
o a
W
ir
eless R
eader I
n
ter
fac
e
(WRI400) or
W
ir
eless S
ta
tus
M
onit
or (
WSM400),
this label
should be r
eplac
ed with the
appr
opr
ia
te devic
e inf
or
ma
tion.
Con
tac
t y
our local author
iz
ed dealer
or visit
w
w
w
.schlage
.c
om/suppor
t
RESET
S3
RELAY 1
RELAY 2
RELA
Y 3
LINK
S2
SCHLAGE
S1
LED2
USB
DEBUG
LED1
LED3
RX
/ TX
STRIKE
AUX
ALARM
LED4
LED5
LED6
LED7
1
1
J6
J2
RELA
Y
ST
ATUS
Factory Default Reset
Pr
ess
a
nd
h
ol
d
BOTH SCHLAGE
and
LINK
buttons for
3 secs.
Coupl
in
g
Pr
ess
a
nd
h
ol
d
SCHLAGE
button, press
LINK
button
3 times
within
5 secs
. Coupling window is enabled for
30 secs
.
Co
ns
tr
uc
tio
n-
M
od
e
Programming
To program a master construction credential *:
Pr
ess
a
nd
h
ol
d
SCHLAGE
button, then present valid credential to the reader within 5 secs. If the credential is not
presented within 5 seconds, time-out will occur.
* N
ote
:
CT5000 must be
in
fa
ct
or
y
de
fa
ul
t s
ta
te
to
p
ro
gr
am
th
e
ma
st
er
construction credential.
To
p
ro
gr
am
each
u
se
r c
onstruction
c
re
de
nt
ia
l
:
Present the master construction credential to the reader. The DEBUG LED will light green. Present the credential to be programmed to the reader within 20 seconds or time-out will occur.
Sequenced Operations
Test
While holding the
SCHLAGE
button, press and release
RESET
button
.
All relays, onboard LEDs, reader LEDs, and reader beeper will remain active while the
SCHLAGE
button is pressed.
DEBUG (LED1
)
G
REE
N
f
or
1
se
co
nd
Factory Default Reset
c
om
pl
et
ed
s
ucc
ess
fu
lly
5
Q
ui
ck
G
REE
N
fl
as
he
s
M
as
te
r construction credential
pr
og
ramm
ed
s
ucc
ess
fu
lly / user
construction credential programmed successfully / 20-sec timeout
So
lid
G
REE
N
(20
se
co
nd
s-max
)
W
ai
tin
g
fo
r u
se
r c
onstruction
c
re
de
nt
ia
l,
af
te
r master
p
re
se
nt
ed
Fast GREEN flashing
Co