Schindler 3100/3300/6300
J 43402603 / 01
160/269
Copyright © 2017 INVENTIO AG
4603
TM BENDING STRESS COUNT RESET
Traction media bending stress counter reset
C1:The maintenance person enters a new STM manufacturing date: the
bending counter has been reset (set to 0)
A1:None
4604
TM BENDING STRESS WARNING LIMIT CHANGED
The maximum permitted traction media bending stress count warning limit was
changed. The bending stress warning limit in% of the maximum permitted
bending stress count.
C1: The maintenance person enters a new STM manufacturing date: the
bending counter has been reset (set to 0)
A1: None
4605
TM BENDING STRESS MAXIMUM CHANGED
The maximum permitted traction media bending stress count was changed.
The new maximum permitted bending stress counts.
4606
TM AGING CLOCK FAILURE
The elevator clock is not running or is delayed.
C1:The date of the elevator clock is not set or is wrong. This could be
caused by a loss of mains and battery power.
A1:Set the correct date.
4607
TM MAX AGE WARNING
The age of the traction media approached the end of life, initiate its
replacement.
C1:The age of the traction media reached the defined percentage of the
service limit.
A1:Initiate replacement of traction media before the end of the estimated
lifetime.
4608
TM MAX AGE EXCEEDED
The maximum permitted age of the traction media is exceeded, it shall be
replaced.
C1:The maximum permitted age of the traction media was exceeded.
A1:Replace the traction media.
C2:The elevator clock date is not correct.
A2:Set the correct date.
4610
TM RES STRENGTH MONITORING VIRGIN STORAGE DETECT
Either the master or backup storages for traction media insufficient strength
monitoring is virgin (empty). The virgin storage is initialized with a copy of the
STM Monitoring data.
C1:The controller founds that one of the redundant media does not
contains any data. The controller rebuilds the STM information.
A1:None.
4611
TM RES STRENGTH MONITORING REF KEY MISMATCH
Reference key mismatch of master and backup storages of traction media
insufficient strength monitoring. The reference key consists of the
manufacturing date of the oldest traction media and the commission number.
C1:Commissioning number differs between controller and chip card
A1:Replace chip card with correct commissioning number