Schindler 3100/3300/6300
J 43402603 / 01
132/269
Copyright © 2017 INVENTIO AG
Code
Trip Manager Message
2002
TRIP LEARNING LEVEL MISSING
The number of floor levels counted during the learning trip in upward direction
does not correspond to the one counted with the check in downward direction.
C1:Bad alignment of floor sensors with magnets (KS) or PHS flags in
shaft
A1:Check alignment of magnets (KS) or PHS flags.Check position of floor
sensor. Check magnet to sensor distance.
C2:Bad floor sensor signal transmission
A2:Check general electrical wiring of the floor sensor signal (for
example, connections at KS/PHS, at SDIC7x,..)
C3:Floor sensor(s) defect
A3:Replace floor sensor(s)
C4:Faulty input on the interface board (PCB) for the floor sensor
A4:Replace interface board (SDIC7x)
2003
TRIP LEARNING NUMBER OF LEVELS VARY
C1:The number of floor levels counted during the learning trip in up
direction does not correspond to the one counted during the down
direction checking phase.
A1:Check magnets / PHS flags. Check KS / PHS sensors / cable
2004
TRIP LEARNING LEVEL OUTSIDE ARRAY LIMITS
Indicates that the number of learned floors is invalid
C1:The number of learned floors exceeded the max floors supported by
the elevator system
A1:Check the number of door zone indicators in the hoistway (for
example, magnets, vanes)
C2:The number of learned floors does not correspond with the
commissioning data
A2:Crosscheck the number of door zone indicators in the hoistway
(for example, magnets, vanes) with the allowed number of floors
according the commissioning data
2005
TRIP POSITION TARGET NOT REACHED
The elevator has finished a trip but the car is signalized by the hoistway
information system not to be in door zone.
C1:Different causes
A1:Check elevator message log for previous reported messages in order
to identify the root cause of the problem.
C2:Signal of door zone detection faulty
A2:Check door zone sensors (for example, PHSx) and wiring.
2006
TRIP WARNING TRIP POSITION TARGET NOT REACHED
*)