27
GB
11. Storage
Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture. Store the operating manual with the elec-
trical tool.
12. Transport
Transport by hand, Fig. 4
For transport, the splitting knife 2 must be completely
moved down. Slightly tilt the log splitter with handle 1 on
the splitting column until the machine is inclined on the
wheels and can be moved.
Transport by crane:
Never lift the machine on the splitting knife!
The machine should operate under the following envi-
ronmental conditions:
minimum
maximum
recom
-
mended
Temperature
5 C°
40 C°
16 C°
Humidity
95 %
70 %
Setting up
Prepare the work place where the machine is to stand.
Create sufficient space in order to allow safe working
without disturbance. The machine has been designed
for working on a level surface. It must therefore be set up
in a stable position on firm ground.
13. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomer‘s mains connection as well as the extension
cable used must also comply with these regula-
tions.
•
The product meets the requirements of
EN 61000-3-11 and is subject to special connec-
tion conditions. This means that use of the product
at any freely selectable connection point is not al-
lowed.
•
Given unfavorable conditions in the power supply the
product can cause the voltage to fluctuate temporarily.
•
The product is exclusively intended for use at con-
nection points that have a continuous current-carry-
ing capacity of at least 100 A per phase.
•
As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets the specified requirements.
Important information
In the event of an overloading the motor will switch itself
off. After a cool-down period (time varies) the motor can
be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
•
Passage points, where connection cables are passed
through windows or doors.
•
Kinks where the connection cable has been improp-
erly fastened or routed.
•
Places where the connection cables have been cut
due to being driven over.
•
Insulation damage due to being ripped out of the wall
outlet.
•
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage reg-
ularly. Make sure that the connection cable does not
hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F“.
The printing of the type designation on the connection
cable is mandatory.
Mains fuse protection is 16 A maximum.
Three-phase motor 400 V / 50 Hz (Fig. 13)
Mains voltage 400 V / 50 Hz
Mains voltage and extension cables must be 5-lead (3P
+ N + SL (3/N/PE).