24 of 44
496339 Issue 4
Factory Defaults
When delivered from the factory, the 8136i is preprogrammed with the
following default settings:
System Users
UO1:
Name = User 01, Access Code 1234, Authority Level A,B,C,D,
System Full Use, Zone omit Permitted, Log Access = Permit-
ted, Change Area and Zone names = Permitted, Change Data
and Time = Permitted, Reset = Permitted
User 02-95:
Not Used (Duress=Disabled)
User 00:
Name - Installer, Access Code = 7890
Installer programming
Menu 10:
Account Name = No Name
Menu 20:
Zone expansion = Default to whichever expander card is
fitted
Menu 30:
Program zones
Menu 31:
Zone Names = ZO1: Zone 001 (all other zones to Zone [nnn])
Menu 32:
Zone Options = All zones Not Used (NU)
Menu 34:
Area Names = Area 01: Area 01 (all other Areas to Area [nn])
Menu 35:
Program Partitions = None (No Areas Allocated)
Menu 40:
Program Multi-Flex
Menu 41:
Level Allocation = Level A,B,C,D = None
Menu 42:
Level Exit Mode = All Levels = Timed and terminate (Exit Time
= 10 Seconds)
Menu 43:
Level Entry Time = All Levels 20 Seconds
Menu 44:
Level Flex-Zones = Not Set Up = NU
Menu 45:
Level Alarm response = All Levels = Full Alarm
Menu 46:
Level Re-Arm Operations = All Levels = Never
Menu 47:
Keypad allocation = None
Menu 48:
Common Area Disabled
Menu 49
Common Area Full Set Link = None
Menu 50:
Program outputs
Menu 51:
Program Output Type = OP1 = Bell (Normally Energised) All
other outputs NO Function
Menu 52:
Program Sounder = Follows Bell
Menu 53:
Partition Bell times = Delay = 0, Bell Time = 20 Minutes
Menu 54:
Entry / Exit Tones = Enabled
Menu 55:
Lighting On Time = 2 Minutes
Menu 56:
Tamper Return = Single wire (closed circuit)
Menu 60:
Program System Options
Factory Defaults
8136