496339 Issue 4
5 of 44
Siren
= 750mA.
Batt (reverse connection) = 2,500mA.
OP1, OP2, OP3, and OP4 are voltage free, single pole relay contacts rated
24VDC @ 3A.
Battery
Recommended Standby
Battery
= 12 Volt, 7.0AH (min) 17AH (max) re-
chargeable lead-acid, Gel Type battery.
Battery Space
= h x w x d 190 x 205 x 75mm.
Keypad Wiring
Recommended maximum distances for the remote keypads from the end
station, using standard alarm cable is 300 metres per branch for a star
configuration.
For a daisy chain configuration the maximum length must take account of the
number of keypads sharing the cable. In general, a single keypad can be
connected at the end of a maximum of 300 meters of standard cable. If you
wish to connect more keypads the cable must be shorter, or the 0V wire must
be thicker. Ensure that at the last keypad the voltage between 0V and 12V
wires is no less than 10.5V.
FSL Zone Wiring
The recommended maximum distance for FSL zones using standard alarm
cable is 300m.
IDIS Zone Wiring
The maximum cable length for a single IDIS loop, including spurs, is 500m.
Greater distances can be achieved by installing a remote power supply to
power detectors, or by using either a special HD bearer cable (Black and Red
power cores of 16/0.20 mm).
Software Limits
The 8136i can support:
•
From one to four Partitions.
•
One to four Levels.
•
One to fifteen keypads.
•
Eight Areas in total. Note that two Partitions cannot share an Area.
•
A minimum of eight zones provided by the end station PCB up to a
maximum of 136 zones with the aid of an IDIS Expander Card.
8136
Battery