background image

 

 
 
 
 
 
 
 
 
 
 

OPERATING AND MAINTENANCE MANUAL 

ISSUE 1 

 

 
 
 
 
 
 
 
 

 

SCANMAX 25 C 

 

DESK TOP CABINET  

SECURITY X-RAY SCREENING SYSTEM 

FITTED WITH COLOUR CAMERA  

(230V) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

SCANNA MSC LIMITED 
104 New Bond Street    Telephone   Facsimile 
London    Nat:  0207 355 3555  Nat:   0207 355 3556 
W1Y 9LG    Int.:  (00 +44) 207 355 3555 Int.:  (00 +44) 207 355 3556 
United Kingdom 

Содержание SCANMAX 25 C

Страница 1: ...C DESK TOP CABINET SECURITY X RAY SCREENING SYSTEM FITTED WITH COLOUR CAMERA 230V SCANNA MSC LIMITED 104 New Bond Street Telephone Facsimile London Nat 0207 355 3555 Nat 0207 355 3556 W1Y 9LG Int 00 4...

Страница 2: ...Date Amendment No Page No Details...

Страница 3: ...shielding the user should be aware that the useful beam can constitute a distinct hazard if not employed in strict accordance with instructions contemplated to provide maximum safety for the operator...

Страница 4: ...NG INSTRUCTIONS 13 X RAY SCREENING PROCEDURES 14 MAINTENANCE 16 Line grounding and regulation 16 Fuse replacement 16 X ray Generator and Controller replacement 17 Door Adjustment 18 Camera adjustment...

Страница 5: ...delivered items not passing through the central mailroom The SCANMAX 25 is completely self contained and can be put into operation immediately and can examine the contents of a parcel 40 x 50 cm 16 x...

Страница 6: ...y notify the carrier at your location UNPACKING THE SCANMAX 25 To remove the SCANMAX from the shipping crate perform the following 1 Undo the binding and open the box with the help of a large screwdri...

Страница 7: ...d replace the screws into the unit Do not operate the unit with the handles fitted Do not attempt to open the door on the Scanmax 20 with the rear handle fitted WARNING When lifting the unit extreme c...

Страница 8: ...ll be set at 230V unless otherwise instructed and should therefore only be operated from a 230V mains supply Connecting to a different mains voltage will result in improper operation or even destructi...

Страница 9: ...ocks have been operated and that the equipment is ready for use 6 Perform interlock check by doing the following Activate the red X RAY ON button on the front control panel Observe that all X ray ligh...

Страница 10: ...on an inadequate support or try to lift it unaided If the unit is dropped do not attempt to resume operation before consulting a qualified service technician The user must be aware that excessive radi...

Страница 11: ...m until it has been checked by a suitably qualified engineer and a successful radiation check carried out 6 In the event of any concern regarding the safe operation of the SCANMAX contact your supplie...

Страница 12: ...w x ray dose X ray beam limiting Interlock system X ray On indicators Lead Shielding In the United Kingdom the requirement is a leakage rate as low as is practicable but in no case to exceed 1 micro S...

Страница 13: ...the area for closer examination and press the left hand key and the image will be enlarged by a factor of 2 Zoom x 2 If a further close look is required press the left hand key again for x4 or x8 and...

Страница 14: ...the camera to synchronise to the monitor Lines will appear across the film if it not synchronised to ensure good depth of field black and white film will tend to give higher apparent contrast If used...

Страница 15: ...ted should be treated with extreme caution 4 If the item appears suspicious security staff should be alerted and the appropriate security procedures implemented SCANNA strongly recommend that users of...

Страница 16: ...formed by the customer Line Grounding and Regulation Regulation When the unit is energised the line voltage should drop no more than 5 at the wall outlet Any further drop indicates that your AC power...

Страница 17: ...connect the in line plug socket to the x ray source S4 Remove the x ray generator from the case Caution The x ray generator is heavy two persons are required for this task S5 Pack the x ray generator...

Страница 18: ...m left to right if needed S4 Test for radiation leakage and correct as needed You must reject the unit at this point if levels of 1 Sv hr are exceeded Final re seating of the door should be performed...

Страница 19: ...until the image on the screen is suitable Remember to return to f1 6 before replacing the side panel The camera lens can be focused on its own image reflected from the lead glass in the base of the i...

Страница 20: ...View of front panel View of rear panel From Left 1 Mains input with fuse under 2 Mains isolating switch 3 Mains for Monitor if applicable From bottom 4 Remote X ray On 5 SVGA video Out 6 Trackball...

Страница 21: ...View of controller with rear panel open...

Страница 22: ...e regulations Equipment Serial No Item Check Result Comment 1 Check Indicators 2 Check switch operation 3 Check door operation and interlock 4 Clean equipment internally 5 Check X ray generator 6 Chec...

Страница 23: ...18 Area Back Panel Area Lid Back No Name No Name 4 5 4 Left Vertical Seam 19 Back Lid Seam 5 Right Vertical Seam 20 Right Lid Seam 6 6 Back Panel Top 19 21 Front Lid Seam 7 Electrical Plug 22 Left Li...

Страница 24: ...110 100 VAC 10 50 60 HZ Single Phase X Ray Source Focal Spot 1 5 mm Anode Angle 35 degrees Anode Type Stationary Kvp 65 KV 85KV max Tube Current 7 mA 20mA max Cooling method Oil cooled Resolution 36 A...

Страница 25: ...stem Internal Resolution 752 X 582 Lens Mount C Mount Minimum illumination 0 02 Lux F1 4 Output Voltage will work to 0 011x Cpu BOARD 2MB DRAM 512KB Flash 30 150 MIPS Video Output Monochrome CCIR Colo...

Страница 26: ...2 lux for excellent picture quality Picture burn in does not occur Excellent immunity to vibration and shock The camera interface uses solid state components and requires no periodical maintenance wor...

Страница 27: ...REPAIRS A one year warranty is provided on the labour performed and any new parts installed by service technician at SCANNA s premises This warranty is limited to labour performed and parts installed...

Страница 28: ...O 1 Don t try to open it 1 Keep calm 2 Don t press squeeze or prod it 2 Look for sender s name on the back 3 Don t put it in sand or water 3 Check with the sender 4 Don t put it in a container 4 Check...

Страница 29: ...oor open If faulty replace fuse blows again check with door closed Check bulb If faulty replace Change controller and x ray generator If faulty replace 2 System Ready Is System Ready light on No Check...

Страница 30: ...faulty replace 3 Dim Picture Is there a large object in the viewing chamber Remove and check with an empty chamber Is fluorescent screen damaged Replace fluorescent screen Is the TV Camera lens dirty...