with space requirements.
•
The work surface is made of a heat-resistant and insulated material.
•
If the hob is installed above an oven, the oven has a built-in cooling fan.
•
The installation will comply with all clearance requirements and applicable
standards and regulations.
•
A suitable isolating switch providing full disconnection from the mains
power supply is incorporated in the permanent wiring, mounted and
positioned to comply with the local wiring rules and regulations.
•
The isolating switch must be of an approved type and provide a 3 mm air
gap contact separation in all poles (or in all active [phase] conductors if the
local wiring rules allow for this variation of the requirements).
•
The isolating switch will be easily accessible to the customer with the hob
installed.
•
You
should
consult local building authorities if in doubt regarding
installation.
•
You use heat-resistant and easy-to-clean finishes (such as ceramic tiles) for
the wall surfaces surrounding the hob.
9.3 After installing the hob, make sure that
•
The power supply cable is not accessible through cupboard doors or
drawers.
•
There is adequate flow of fresh air from outside the cabinetry to the base
of the hob.
•
If the hob is installed above a drawer or cupboard space, a thermal
protection barrier is installed below the base of the hob.
•
The isolating switch is easily accessible by the customer.
9.4 Before locating the fixing brackets
The unit should be placed on a stable, smooth surface
.
Do not apply force
onto the controls protruding from the hob.
9.5 Adjusting the bracket position
Fix the hob on the
table top
by screw 2 brackets on the bottom of hob(see
picture) after installation.
57