AccuPro-5000
™
MEASUREMENT SYSTEM OPERATOR MANUAL
Issued by Department:
Engineering
Doc. Number:
5000-00-00-002
Revision:
02
Effective Date:
10/05/2021
File: 5000-00-00-002-r2_
AccuPro_5000_Operator_Manual
Copyright© 2021 Scaletron Industries, Ltd
All Rights Reserved
Page
47
of
63
Figure 28: LIQUID MASS Control Flow Diagram
a.
For a dual-channel system, first select the desired channel for which to conduct the procedure. The
number of any chosen active channel will be indicated in the upper-left corner of the display for the
remainder of this submenu.
b.
Select whether the Liquid Mass value to be entered represents a known density (weight/volume) or
specific gravity (unitless) value. If this submenu is being entered for the first time, or if a change in
the unit is detected, the default Liquid Mass value will be that of pure water, whether it be
represented as a density (8.34540 lb/gal) or specific gravity (1.00000).
c.
If a Liquid Mass density is to be entered, select whether the density units are pounds/gallon (lb/gal)
or kilograms/liter (kg/l).
d.
Enter a Liquid Mass value as selected representing either a density or specific gravity.
8.9
Tare Adjust / Tare Secured
Select this menu option by pressing the Enter Key while the display appears as shown in Figure 29.
Path taken when ENTER Key pressed.
Path taken when ARROW Key pressed.
Changes Value in
Selected Unit
Changes Value
(Unitless)
EXIT
EXIT
1: DENSITY
Unit? kg/l
1: DENSITY
8.34540 lb/gal
1: LIQUID MASS
Unit? Density
1: DENSITY
Unit? lb/gal
1: SPEC GRAVITY
1.00000
1: LIQUID MASS
Unit? Sp Grav