4.7
Relay Output Board (Dual or Quad Relays)
With reference to Figure 8, the optional ROB offers two configurations
–
one having two relays (Dual)
and another having four (Quad). A dual configuration supports relays numbered #1 and #2. A quad
configuration supports relays numbered #1 through #4. The contacts of each relay are wired in a SPDT
configuration as shown in
, with external wire connections made accessible via a 3-position
terminal block.
CONTACT LABEL
DESCRIPTION
NO
Normally-Open contact
COM
Common contact
NC
Normally-Closed contact
Table 7: Relay Interface
The relays are initialized in a negated, or de-energized, state following power-up. They are
independently asserted, or energized, based on user-defined setpoints and other criteria. The assertion
of a dedicated status LED indicates when the respective relay is energized.
Note that the ROB contains no Flash memory device, therefore all configuration data is saved to the
respective channel’s AIB.
Figure 8: Relay Output Board
Relay Interface
Dual (2x)
Quad (4X)
Status LEDs (4x)