IPB50 BASIC FUNCTIONS
SEMI-AUTOMATIC TARE
By pressing the
TARE
key any weight value present on the display is zeroed, the “NET” LED will now turn on.
To cancel the stored tare value, press
TARE
or
ZERO
without load. Each subsequent pressing of TARE will
replace the previously stored value.
NOTE:
The tare operations are disabled in the SETPOINT ON GROSS WEIGHT functioning Fn.
PRINTING
If a printer is connected to either instrument, by pressing the PRINT key, GROSS, TARE and NET weight will
be printed. If no manual TARE was entered only the gross weight will be printed.
The print can be executed only with a weight stable and different from zero.
It is possible to select the language of the printouts .
Besides the described printouts, each single Fn can execute specific print (refer to FUNCTIONING).
TICKET NUMBER
In the printout it is possible to include the TICKET NO. (USER SET-UP parameter
ntlk
), a progressive number
which increases every time the
↵
/PRINT key is pushed; it may be any number between 1 and 65535 which is
kept in memory even when the instrument is turned off.
To zero the TICKET NO. one must go to the “
ntlk
” parameter in USER SET-UP and select
rEStl
and push
↵
.
The TICKET NO. is printed before the date/hour, and may be used in all functioning Fns and in the totalizer Fn
it increases only with the resetting of the total.
PRINT OF HEADING
In order to enter the heading one needs the IPBC TOOL software; this allows to control through the PC the
configurations of the IPB50 (using an optional connection cable with the bidirectional serial port). The
programme screen is subdivided into metrological parameters, non metrological parameters, user SETUP, and
heading. Following the instructions of this manual, it is possible to enter up to 4 lines of heading, each of 24
characters with a variable height (height 1 or height 2).
Within the user SETUP of the instrument, if one selects PrON or PrES, the following step displayed is “IntES”:
at this point, by confirming with
↵
, it is possible to select:
Int SI
Prints the heading if the total is 0 (in the totalization programme)
Int F1
Always prints the heading
Int nO
Does not print the heading