IPB50
12
VIEWING THE APW
(
average piece Weight
)
After carrying out the reference operation it is possible to view on the display the calculated APW or the one
manually inserted. While the scale shows the number of pieces, if one presses Fn, the display shows the
WEIGHT on the weighing system; when one press Fn again the APW= is displayed. At this point by pressing
↵
once, the digits before the decimal place are shown, while pressing
↵
a second time the digits after the
decimal place are shown.
For example, if the unit of measure of the scale is kg, after carrying out the reference operation, by pressing
Fn twice the display shows APW=; if one now presses
↵
the digits of the APW before the decimal place are
shown, 0 for example; by pressing
↵
again, the digits after the decimal place are shown, which could be
60000 for example; in this case the APW, or the weight of each piece is 0.60000 kg. To return to the counting
function, press Fn (or
↵
) again: the display will show “- S – CP”; now press
↵
to confirm and return to the
counting function with the same APW previously calculated
PRINTING UNDER COUNTING Fn
If a printer is present, pressing the
↵
key will print the values of GROSS weight, TARE weight, NET weight on
the scale, the Quantity of PIECES (PCS) on the scale, plus the APW (calculated or entered by user) in kg, g, t,
or lb. The ticket number is also printed (if enabled in the ntlk step of the USER SET-UP)
NOTE:
If
↵
is pressed with the scale in weight Fn (for instance by pressing Fn to exit counting Function), only
the values of GROSS weight, TARE weight, NET weight on the scale will print.
STANDARD (Std)
Normal weighing Fn: by pressing "Fn" key the value is converted from kg to lbs and vice versa. Their relative
LED displays the appropiate unit. Only this Fn has the ability to convert from kg to lbs and back again.
However, the other Fns may be chosen in either unit of measure during configuration beforehand.
NET/GROSS (NtgS)
(the tare value is lost when the IPB is switched off)
Press the key ->T<- to display the net Value 0 (led NET is ON), however with the Fn key having a net/gross
switch. If there is a pre-set tare, by pressing the Fn key, for a 3 second interval, the gross weight is displayed,
the net weight LED is turned off and the pre-set measuring units is flashing.
TAKE NOTE
:
While the gross weight is being viewed it is not possible to print.
SET POINT
StPG (setpoint on the gross it is not possible to tare) / StPn (setpoint on the net)
Press the Fn key to modify the values of the 2 setpoints.
Setpoints without hysteresis (IStno selected)
–
The display shows " StP1 " (setpoint 1) press
↵
, the display shows the value of setpoint 1.
–
Use the Fn key to choose the digit to be increased (BLINKING DIGIT), the scrolling of the digits takes
place from right to left.
–
Increase the value using the ->T<- key.
–
When finished entering the values, confirm with
↵
.
–
The display shows " StP2 " (setpoint 2) press
↵
, the display shows the value of setpoint 2.
-- adjustment idem setpoint1.
Setpoints with hysteresis (IStnI selected)
one enters two SETPOINTS for each relay: a DISABLING one, which, (when the gross weight is lower than it,
disables the appropriate relay); an ENABLING one, (when the gross weight is equal or greater than it, it
enables the appropriate relay). By keeping pressed the
↵
key for about 3 seconds one enters the four SET
POINT values (DISABLING and ENABLING of relay 1, DISABLING and ENABLING of relay 2):
–
The display shows " SP1OF " (relay 1 DISABLING SETPOINT): press
↵
to enter the Step.
–
Use the Fn key to choose the digit to be increased (BLINKING DIGIT), the scrolling of the digits takes
place from right to left.