background image

 

‐ 

4

 ‐ 

hold

 

for

 

2

 

sec

 

sec.)

 

until

 

60

 

sec.

 

timeout

 

or

 

illumine

 

3

 

sec.

 

after

 

successful.

 

Press

 

and

 

hold

 

for

 

2

 

sec.

 

 

 

illumine

 

7

 

Create

 

Associated

 

Device

 

in

 

group

 

#4~#6

 

Press

 

3

 

times

 

in

   

2

 

sec

 

 

 

 

Blink

 

on

 

1

 

time

 

slowly

 

(0.5

 

second

 

on,

 

3

 

second

 

off)

 

until

 

60

 

sec.

 

timeout

 

or

 

illumine

 

3

 

sec.

 

after

 

successful.

 

Press

 

and

 

hold

 

for

 

2

 

sec.

 

 

 

Illumine

 

8

 

Delete

 

Associated

 

Device

 

in

 

group

 

#4~#6

 

 

Press

 

3

 

times

 

in

 

2

 

sec

 

 

 

Blink

 

on

 

2

 

times

 

slowly

 

(0.5

 

second

 

on

 

twice,

 

3

 

second

 

off)

 

until

 

60

 

sec.

 

timeout

 

or

 

illumine

 

3

 

sec.

 

after

 

successful.

 

9

 

Control

 

turn

 

on

 

device

 

in

 

group

 

#4

 

Press

 

1

 

time

 

 

 

 

10

 

Control

 

turn

 

off

 

device

 

in

 

group

 

#5

 

 

Press

 

1

 

time

 

 

 

11

 

Control

 

turn

 

stop

 

device

 

in

 

group

 

#5

 

 

 

 

Press

 

1

 

time

 

12

 

Control

 

central

 

scene

 

trigger

 

Press

 

1/2/3

 

times

 

in

 

2

 

sec.

 

or

 

hold

 

on

 

for

 

2

 

sec.

 

or

 

release

 

any

 

one

 

of

 

key.

 

13

 

Notification

 

Alarm

 

Event

 

trigger

 

 

 

Press

 

1

 

time

 

 

14

 

Notification

 

Alarm

 

Event

 

clear

 

 

 

Press

 

and

 

hold

 

for

 

2

 

sec.

 

 

Blink

 

on

 

1

 

times

 

(0.5

 

second

 

on,

 

0.5

 

second

 

off).

 

15

 

Un

protect

 

Keyboard

 

 

 

Press

 

and

 

hold

 

for

 

2

 

sec.

 

Illumine

 

for

 

3

 

second

 

indicator

 

un

protected.

 

16

 

Keyboard

 

has

 

protected

 

Press

 

or

 

hold

 

any

 

key

 

Blink

 

on

 

3

 

times

 

(0.5

 

second

 

on,

 

0.5

 

second

 

off).

 

 

[Note:]

   

Item

 

1~2,

 

15,

 

16

 

is

 

available

 

while

 

key

fob

 

in

 

Idle

 

state;

 

item

 

3~4

 

is

 

available

 

as

 

key

fob

 

is

 

primary

 

or

 

installer

 

controller,

 

Item

 

5

 

is

 

available

 

as

 

key

fob

 

is

 

primary

 

controller

 

only;

 

item

 

6

 

is

 

available

 

as

 

key

fob

 

hasn’t

 

add

 

any

 

node,

 

item

 

9~11

 

is

 

available

 

in

 

anytime;

 

item

 

7~8,

 

12~

 

14

 

is

 

available

 

as

 

key

fob

 

was

 

added

 

in

 

other

 

controller.

 

 

 

z

 

Z

Wave

 

Network

 

Setup

 

[Note:]

 

It

 

is

 

recommended

 

implement

 

setup

 

operation

 

after

 

new

 

battery

 

is

 

replaced

 

to

 

ensure

 

battery

 

is

 

powerful

 

for

 

setup

 

procedure.

 

„

 

Reset

 

factory

 

default

 

1)

 

Press

 

and

 

hold

 

both

 

 

and

 

 

key

 

together

 

for

 

2

 

seconds

 

until

 

LED

 

indicator

 

light

 

on,

 

release

 

all

 

key;

 

2)

 

Press

 

and

 

hold

 

both

 

 

and

 

 

key

 

together

 

for

 

10

 

seconds,

 

during

 

hold

 

time

 

LED

 

will

 

blink

 

off

 

0.5

 

second

 

interval

 

2

 

seconds.

 

After

 

hold

 

10

 

seconds

 

LED

 

indicator

 

light

 

off,

 

then

 

release

 

all

 

keys,

 

factory

 

default

 

is

 

retrieve,

 

LED

 

indicator

 

will

 

flashes

 

three

 

times

 

after

 

restore

 

factory

 

default

 

success.

 

 

[Note:]

   

After

 

restore

 

factory

 

default,

 

the

 

product

 

reset

 

all

 

included

 

and

 

associated

 

devices,

 

and

 

acting

 

as

 

portable

 

primary

 

controller.

 

Please

 

use

 

this

 

procedure

 

only

 

when

 

the

 

network

 

primary

 

controller

 

is

 

missing

 

or

 

otherwise

 

inoperable.

 

Содержание Key-fob

Страница 1: ...o master controller and it can associated control devices by key fob local operation or master controller association set configuration The product is Z Wave wireless accessible and it can quickly easily included and operated in any Z Wave network with other Z Wave certified devices from any other manufacturers All non battery operated nodes within the network will act as repeaters regardless of v...

Страница 2: ...iated from GUI of the master controller Secure vs no Secure add to Z Wave Network The production is a security enabled Z wave Plus production implements Z Wave Application Security Layer in accordance with Z Wave protocol This device must be used in conjunction with a Security Enabled Z Wave Controller in order to fully implemented secure functions Even though the functionality and support command...

Страница 3: ... Function Description LED indicator Press and hold for 2 sec Illumine 1 Reset Factory Default Press and hold for 10 sec Blink off 0 5sec interval 2 second while hold until flash on 3 times Press and hold for 2 sec Illumine 2 Wakeup key fob manually and send battery report to lifeline group 1 Press 3 times in 2 sec Flash on fast 3 times then keep in wakeup for 30 second w o initial wakeup parameter...

Страница 4: ...rotected Press or hold any key Blink on 3 times 0 5 second on 0 5 second off Note Item 1 2 15 16 is available while key fob in Idle state item 3 4 is available as key fob is primary or installer controller Item 5 is available as key fob is primary controller only item 6 is available as key fob hasn t add any node item 9 11 is available in anytime item 7 8 12 14 is available as key fob was added in...

Страница 5: ...ce procedure Remove Z Wave Device from key fob 1 Press and hold both and key together for 2 seconds until LED indicator light on release all key 2 Press and hold key for 2 seconds until LED indicator flash quickly 1 second on 1 second off key fob starts remove device processing 3 Refer to device manual trigger the device which is going to included start network add remove mode 4 If key fob detects...

Страница 6: ... if there not any controller was detected Note Key fob s learn mode is only available as it has not added any device before or has included in master controller already Key fob always ignores Basic Set Get command requires from other controller Note Press and hold on key for 2 seconds after step 3 would terminal procedure if Z Wave adding processing has not started Remove key fob from other Z Wave...

Страница 7: ...vice from group 2 4 together and LED indicator light on for 3 seconds after delete association successful If key fob has not detects any device in 60 seconds exit delete associated device process and LED indicator goes off Note Key fob s delete associated locally function is only available as it was included in other master controller Key fob always deletes the associated device with endpoint toge...

Страница 8: ...C_CONTROLLER Specific Device Type SPECIFIC_TYPE_PORTABLE_REMOTE_CONTROLLER Support Command Class COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_WAKE_UP COMMAND_CLASS_SECURITY COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CL...