background image

 

‐ 

7

 ‐ 

3)

 

Refer

 

to

 

device

 

manual,

 

trigger

 

the

 

device

 

which

 

is

 

going

 

to

 

associated

 

start

 

network

 

add/remove

 

mode;

 

4)

 

If

 

key

fob

 

detects

 

any

 

device

 

started

 

network

 

add/remove

 

mode,

 

it

 

associate

 

the

 

device

 

into

 

group

 

#2~#4

 

together

 

and

 

LED

 

indicator

 

light

 

on

 

for

 

3

 

seconds

 

after

 

association

 

successful;

 

If

 

key

fob

 

has

 

not

 

detects

 

any

 

device

 

in

 

60

 

seconds,

 

exit

 

associate

 

device

 

process

 

and

 

LED

 

indicator

 

goes

 

off.

 

[Note:]

   

Key

fob’s

 

associate

 

locally

 

function

 

is

 

only

 

available

 

as

 

it

 

was

 

included

 

in

 

other

 

master

 

controller.

 

Please

 

refer

 

to

 

the

 

master

 

controller

 

GUI

 

manual

 

setup

 

associate

 

device

 

with

 

endpoint

 

in

 

order

 

to

 

control

 

device’s

 

endpoint.

 

 

„

 

Delete

 

associated

 

device

 

from

 

association

 

group

 

of

 

#2~#4

 

together

 

locally

 

1)

 

Press

 

and

 

hold

 

both

 

 

and

 

 

key

 

together

 

for

 

2

 

seconds

 

until

 

LED

 

indicator

 

light

 

on,

 

release

 

all

 

key;

 

2)

 

Press

 

 

key

 

3

 

times

 

in

 

2

 

seconds,

 

LED

 

indicator

 

blink

 

on

 

2

 

times

 

interval

 

3

 

second

 

(0.5

 

second

 

on

 

twice,

 

3

 

second

 

off),

 

key

fob

 

starts

 

delete

 

associated

 

device

 

processing;

 

3)

 

Refer

 

to

 

device

 

manual,

 

trigger

 

the

 

device

 

which

 

is

 

going

 

to

 

delete

 

associated

 

start

 

network

 

add/remove

 

mode;

 

4)

 

If

 

key

fob

 

detects

 

any

 

device

 

started

 

network

 

add/remove

 

mode,

 

it

 

delete

 

associate

 

of

 

the

 

device

 

from

 

group

 

#2~#4

 

together

 

and

 

LED

 

indicator

 

light

 

on

 

for

 

3

 

seconds

 

after

 

delete

 

association

 

successful;

 

If

 

key

fob

 

has

 

not

 

detects

 

any

 

device

 

in

 

60

 

seconds,

 

exit

 

delete

 

associated

 

device

 

process

 

and

 

LED

 

indicator

 

goes

 

off.

 

[Note:]

   

Key

fob’s

 

delete

 

associated

 

locally

 

function

 

is

 

only

 

available

 

as

 

it

 

was

 

included

 

in

 

other

 

master

 

controller.

 

Key

fob

 

always

 

deletes

 

the

 

associated

 

device

 

with

 

endpoint

 

together.

 

 

z

 

Operation

 

„

 

Control

 

turn

 

on,

 

off,

 

stop

 

device

 

1)

 

Press

 

 

or

 

 

or

 

 

key

 

1

 

time,

 

key

fob

 

send

 

the

 

specify

 

command

 

(on/off/stop)

 

to

 

the

 

association

 

group

 

(#2

 

/

 

#3/#4)

 

device

 

corresponding

 

pressed

 

key,

 

LED

 

indicator

 

flash

 

until

 

send

 

out

 

command

 

to

 

all

 

devices

 

complete.

 

 

„

 

Notification

 

alarm

 

report

 

1)

 

Press

 

 

key

 

1

 

time,

 

key

fob

 

send

 

notification

 

alarm

 

command

 

to

 

association

 

group

 

(#1)

 

device,

 

LED

 

indicator

 

flash

 

until

 

send

 

out

 

command

 

to

 

all

 

devices

 

complete.

 

2)

 

Press

 

and

 

hold

 

 

key

 

for

 

2

 

second,

 

key

fob

 

send

 

notification

 

event

 

clear

 

command

 

to

 

association

 

group

 

(#1)

 

device,

 

LED

 

indicator

 

flash

 

until

 

send

 

out

 

command

 

to

 

all

 

devices

 

complete.

 

 

„

 

Central

 

scene

 

trigger

 

1)

 

Press

 

 

or

 

 

or

 

 

or

 

 

key

 

several

 

times

 

in

 

2

 

seconds,

 

key

fob

 

send

 

the

 

specify

 

central

 

scene

 

report

 

command

 

to

 

association

 

group

 

(#1)

 

device

 

corresponding

 

key

 

press

 

operation,

 

LED

 

indicator

 

flash

 

until

 

send

 

out

 

command

 

to

 

all

 

devices

 

complete.

 

 

z

 

Technical

 

Parameters

 

Operating

 

voltage:

   

3V

 

(Battery

 

Type:

 

CR2032)

 

Quiescent

 

current:

   

4uA

 

Alarm

 

current:

   

20mA

 

Содержание Key-fob

Страница 1: ...o master controller and it can associated control devices by key fob local operation or master controller association set configuration The product is Z Wave wireless accessible and it can quickly easily included and operated in any Z Wave network with other Z Wave certified devices from any other manufacturers All non battery operated nodes within the network will act as repeaters regardless of v...

Страница 2: ...iated from GUI of the master controller Secure vs no Secure add to Z Wave Network The production is a security enabled Z wave Plus production implements Z Wave Application Security Layer in accordance with Z Wave protocol This device must be used in conjunction with a Security Enabled Z Wave Controller in order to fully implemented secure functions Even though the functionality and support command...

Страница 3: ... Function Description LED indicator Press and hold for 2 sec Illumine 1 Reset Factory Default Press and hold for 10 sec Blink off 0 5sec interval 2 second while hold until flash on 3 times Press and hold for 2 sec Illumine 2 Wakeup key fob manually and send battery report to lifeline group 1 Press 3 times in 2 sec Flash on fast 3 times then keep in wakeup for 30 second w o initial wakeup parameter...

Страница 4: ...rotected Press or hold any key Blink on 3 times 0 5 second on 0 5 second off Note Item 1 2 15 16 is available while key fob in Idle state item 3 4 is available as key fob is primary or installer controller Item 5 is available as key fob is primary controller only item 6 is available as key fob hasn t add any node item 9 11 is available in anytime item 7 8 12 14 is available as key fob was added in...

Страница 5: ...ce procedure Remove Z Wave Device from key fob 1 Press and hold both and key together for 2 seconds until LED indicator light on release all key 2 Press and hold key for 2 seconds until LED indicator flash quickly 1 second on 1 second off key fob starts remove device processing 3 Refer to device manual trigger the device which is going to included start network add remove mode 4 If key fob detects...

Страница 6: ... if there not any controller was detected Note Key fob s learn mode is only available as it has not added any device before or has included in master controller already Key fob always ignores Basic Set Get command requires from other controller Note Press and hold on key for 2 seconds after step 3 would terminal procedure if Z Wave adding processing has not started Remove key fob from other Z Wave...

Страница 7: ...vice from group 2 4 together and LED indicator light on for 3 seconds after delete association successful If key fob has not detects any device in 60 seconds exit delete associated device process and LED indicator goes off Note Key fob s delete associated locally function is only available as it was included in other master controller Key fob always deletes the associated device with endpoint toge...

Страница 8: ...C_CONTROLLER Specific Device Type SPECIFIC_TYPE_PORTABLE_REMOTE_CONTROLLER Support Command Class COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_WAKE_UP COMMAND_CLASS_SECURITY COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CL...

Отзывы: