supports

 

notification

 

alarm

 

type

 

of

 

“EMERGENCY=0x0A”

 

and

 

event

 

type

 

of

 

“MEDICAL=0x03”

 

as

 

it

 

was

 

added

 

in

 

other

 

Z

Wave

 

system

 

and

 

associated

 

group

 

1#.

 

 

„

 

Protect

 

key

fob’s

 

keyboard

 

User

 

can

 

protect

 

key

fob’s

 

keyboard

 

avoid

 

un

want

 

press

 

key

fob

 

keyboard.

 

Factory

 

default

 

un

protect

 

the

 

keyboard,

 

user

 

can

 

re

configuration

 

protect

 

timeout

 

value

 

between

 

30

 

second

 

to

 

60

 

second

 

to

 

enable

 

keyboard

 

protect

 

function.

 

From

 

last

 

key

fob

 

operation

 

complete

 

protect

 

timeout

 

or

 

received

 

protect

 

command

 

from

 

master

 

controller;

 

key

fob’s

 

keyboard

 

was

 

protected

 

no

 

more

 

keyboard

 

except

 

un

protect

 

sequence

 

is

 

acceptable.

 

 

„

 

Advance

 

Configuration

 

The

 

product

 

supports

 

configuration

 

command

 

setting

 

parameter

 

as

 

following:

 

Parameter

 

No#

 

Hex

 

(Dec)

 

Data

 

Size

 

(Byte)

 

Acceptable

 

Set

 

/

 

Get

 

Parameter

 

Value

 

Description

 

0x01

 

(1)

 

1

 

Get

 

/

 

Set

 

30

 

 

60

 

Protect

 

timeout,

 

in

 

second.

 

Default=30;

 

valid

 

value=30~60

 

second.

 

 

 

z

 

Quickly

 

Setup

 

 

Key

 

Define

 

Item

 

Function

 

Description

 

 

 

 

 

LED

 

indicator

 

Press

 

and

 

hold

 

for

 

2

 

sec.

 

 

Illumine

 

1

 

Reset

 

Factory

 

Default

 

 

Press

 

and

 

hold

 

for

 

10

 

sec.

 

Blink

 

off

 

(0.5sec)

 

interval

 

2

 

second

 

while

 

hold

 

until

 

flash

 

on

 

3

 

times

 

Press

 

and

 

hold

 

for

 

2

 

sec.

 

 

 

Illumine

 

2

 

Wakeup

 

key

fob

 

manually

 

and

 

send

 

battery

 

report

 

to

 

lifeline

 

(group

 

#1)

 

 

 

Press

 

3

 

times

 

in

 

2

 

sec.

 

Flash

 

on

 

fast

 

3

 

times,

 

then

 

keep

 

in

 

wakeup

 

for

 

30

 

second

 

w/o

 

initial

 

wakeup

 

parameter

 

or

 

10

 

second

 

has

 

initial

 

wakeup

 

parameter.

 

Press

 

and

 

hold

 

for

 

2

 

sec.

 

 

illumine

 

3

 

Add

 

Device

 

into

 

Key

fob

 

Press

 

and

 

hold

 

for

 

2

 

sec

 

 

 

 

Flash

 

on

 

slowly

 

(3

 

second

 

on,

 

3

 

second

 

off)

 

until

 

60

 

sec.

 

timeout

 

or

 

illumine

 

3

 

sec.

 

after

 

successful.

 

Press

 

and

 

hold

 

for

 

2

 

sec.

 

 

illumine

 

4

 

Remove

 

Device

 

from

 

Key

fob

 

 

Press

 

and

 

hold

 

for

 

2

 

sec

 

 

 

Flash

 

on

 

quickly

 

(1

 

second

 

on,

 

1

 

second

 

off)

 

until

 

15

 

sec.

 

timeout

 

or

 

illumine

 

3

 

sec.

 

after

 

successful.

 

Press

 

and

 

hold

 

for

 

2

 

sec.

 

 

 

illumine

 

5

 

Copy

 

to

 

new

 

Controller

 

 

 

 

Press

 

and

 

hold

 

for

 

2

 

sec

 

Intermittently

 

flash

 

(2

 

times

 

@3

 

sec.)

 

until

 

60

 

sec.

 

timeout

 

or

 

illumine

 

3

 

sec.

 

after

 

successful.

 

Press

 

and

 

hold

 

for

 

2

 

sec.

 

 

 

illumine

 

6

 

Add/Remove

 

Key

fob

 

to/from

 

other

 

Z

Wave

 

network

 

 

 

Press

 

and

 

 

Intermittently

 

flash

 

(3times

 

@3

 

Содержание Key-fob

Страница 1: ...o master controller and it can associated control devices by key fob local operation or master controller association set configuration The product is Z Wave wireless accessible and it can quickly easily included and operated in any Z Wave network with other Z Wave certified devices from any other manufacturers All non battery operated nodes within the network will act as repeaters regardless of v...

Страница 2: ...iated from GUI of the master controller Secure vs no Secure add to Z Wave Network The production is a security enabled Z wave Plus production implements Z Wave Application Security Layer in accordance with Z Wave protocol This device must be used in conjunction with a Security Enabled Z Wave Controller in order to fully implemented secure functions Even though the functionality and support command...

Страница 3: ... Function Description LED indicator Press and hold for 2 sec Illumine 1 Reset Factory Default Press and hold for 10 sec Blink off 0 5sec interval 2 second while hold until flash on 3 times Press and hold for 2 sec Illumine 2 Wakeup key fob manually and send battery report to lifeline group 1 Press 3 times in 2 sec Flash on fast 3 times then keep in wakeup for 30 second w o initial wakeup parameter...

Страница 4: ...rotected Press or hold any key Blink on 3 times 0 5 second on 0 5 second off Note Item 1 2 15 16 is available while key fob in Idle state item 3 4 is available as key fob is primary or installer controller Item 5 is available as key fob is primary controller only item 6 is available as key fob hasn t add any node item 9 11 is available in anytime item 7 8 12 14 is available as key fob was added in...

Страница 5: ...ce procedure Remove Z Wave Device from key fob 1 Press and hold both and key together for 2 seconds until LED indicator light on release all key 2 Press and hold key for 2 seconds until LED indicator flash quickly 1 second on 1 second off key fob starts remove device processing 3 Refer to device manual trigger the device which is going to included start network add remove mode 4 If key fob detects...

Страница 6: ... if there not any controller was detected Note Key fob s learn mode is only available as it has not added any device before or has included in master controller already Key fob always ignores Basic Set Get command requires from other controller Note Press and hold on key for 2 seconds after step 3 would terminal procedure if Z Wave adding processing has not started Remove key fob from other Z Wave...

Страница 7: ...vice from group 2 4 together and LED indicator light on for 3 seconds after delete association successful If key fob has not detects any device in 60 seconds exit delete associated device process and LED indicator goes off Note Key fob s delete associated locally function is only available as it was included in other master controller Key fob always deletes the associated device with endpoint toge...

Страница 8: ...C_CONTROLLER Specific Device Type SPECIFIC_TYPE_PORTABLE_REMOTE_CONTROLLER Support Command Class COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_WAKE_UP COMMAND_CLASS_SECURITY COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION COMMAND_CL...

Отзывы: